Application of high-performance liquid chromatography with photodiode array detection to the metabolic profiling of plant isoprenoids
Open accessAbstract
The application of high-performance liquid chromatography (HPLC) using a C30 reverse-phase stationary matrix has enabled the simultaneous separation of carotenes, xanthophylls, ubiquinones, tocopherols and plastoquinones in a single chromatogram. Continuous photodiode array (PDA) detection ensured identification and quantification of compounds upon elution. Applications of the method to the characterization of transgenic and mutant tomato varieties with altered isoprenoid content, biochemical screening of Arabidopsis thaliana, and elucidation of the modes of action of bleaching herbicides are described to illustrate the versatility of the procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rohmer, M., & Rohmer, M. (1999) · Natural Product Reports · doi:10.1039/a709175c · Cited by 1,193
Cited by
Metabolomics—the link between genotypes and phenotypes
Fiehn, O. (2002) · Plant Molecular Biology · doi:10.1023/a:1013713905833 · Cited by 3,445
Simkin, A. J., Schwartz, S. H., Auldridge, M., Taylor, M. G., & Klee, H. J. (2004) · The Plant Journal · doi:10.1111/j.1365-313x.2004.02263.x · Cited by 474
Toledo-Ortiz, G., Huq, E., & Rodríguez-Concepción, M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914428107 · Cited by 453
Unintended effects and their detection in genetically modified crops
Cellini, F., Chesson, A., Colquhoun, I., Constable, A., Davies, H. V., Engel, K. H., Gatehouse, A. M. R., Kärenlampi, S., Kok, E. J., Leguay, J.-J., et al. (2004) · Food and Chemical Toxicology · doi:10.1016/j.fct.2004.02.003 · Cited by 397
Hasunuma, T., Kikuyama, F., Matsuda, M., Aikawa, S., Izumi, Y., & Kondo, A. (2013) · Journal of Experimental Botany · doi:10.1093/jxb/ert134 · Cited by 160
“both chlorophyll a and carotenoids (Fraser et al., 2000), the decrease in the absorbance at 430 nm indicated a decrease in these pigments.”
Metadata
- Authors
- Fraser, P. D., Pinto, M. E. S., Holloway, D. E., & Bramley, P. M.
- Venue
- The Plant Journal
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 24
- Issue
- 4
- Pages
- 551-558
- ISSN
- 0960-7412 (ISSN-L)
- 1365-313X
- OpenAlex
- W1965916795
- Cited by
- 410
- References
- 1
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of high-performance liquid chromatography with photodiode array detection to the metabolic profiling of plant isoprenoids. https://app.cochat.ai/papers/10.1046/j.1365-313x.2000.00896.x
- The paper
- Fraser, P. D., Pinto, M. E. S., Holloway, D. E., & Bramley, P. M. (2000). Application of high-performance liquid chromatography with photodiode array detection to the metabolic profiling of plant isoprenoids. The Plant Journal. https://doi.org/10.1046/j.1365-313x.2000.00896.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.