CoChat

Screening for mast cell tryptase and serum IgE antibodies in 18 patients with anaphylactic shock during general anaesthesia

Dybendal, T., Guttormsen, A. B., Elsayed, S., Askeland, B., Harboe, T., Florvaag, E. · 2003 · Acta Anaesthesiologica Scandinavica
Cited by 78

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: In the perioperative setting multiple agents can cause anaphylaxis. Often the reactions are dramatic, and due to their lifethreatening potential it is crucial that the responsible agent is identified in order to avoid future adverse reactions. The aim of the present study was to measure the concentration of serum mast cell tryptase (MCT), to investigate the prevalence of serum IgE antibodies against ammonium groups, choline, morphine, suxamethonium, thiopentone and latex and to perform skin prick tests (SPTs) in 18 patients experiencing an anaphylactic reaction during induction of general anaesthesia. Methods: Serum samples from 18 patients with an anaphylactic reaction during general anaesthesia were analyzed for MCT and specific IgE against ammonium groups, choline, morphine, suxamethonium, thiopentone and latex. Skin prick tests were performed in 11 out of 18 patients. Results: Ten patients had elevated MCT levels and specific IgE against ammonium ion, morphine and (with the exception of patient nos 3, 9 and 10) suxamethonium. Seven of these patients had positive SPTs to suxamethonium. One of the patients tested positive to latex in addition to suxamethonium. Two patients showed elevated MCT, while specific IgE against the drugs tested was not detected. Three patients tested positive to ammonium ion, morphine and suxamethonium, but negative to MCT. Three patients tested negative to both MCT and specific IgE. Conclusions: Fifteen out of 18 sera tested positive for MCT and/or specific IgE against neuromuscular blocking drugs (NMBDs). Ten of the 18 patients experienced an IgE‐mediated anaphylactic reaction to NMBDs during anaesthesia, verified by detection of specific IgE and elevated levels of MCT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1399-6576.2003.00237.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 78

Metadata

Authors
Dybendal, T., Guttormsen, A. B., Elsayed, S., Askeland, B., Harboe, T., & Florvaag, E.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
2003-11
Volume
47
Issue
10
Pages
1211-1218
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2121688322
Cited by
78
References
2
FWCI
2.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.