CoChat

Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders

Open access
NIEROP, PETER R., VAN MECHELEN, ROB, VAN ELSÄCKER, ANDRÉ, LUIJTEN, RONALD H.M., ELHENDY, ABDOU · 2000 · Pacing and Clinical Electrophysiology
Cited by 86

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

NIEROP, P.R., et al.: Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders. Ambulatory ECG monitoring in patients with recurrent syncope is nondiagnostic in the majority of cases. Recently, an ECG implantable loop recorder (ILR) has been introduced. The ILR performs continuous ECG monitoring over a period of at least 14 months. From February 1997 to September 1999, 35 patients underwent implantation of an ILR. During a mean follow‐up of 11 ± 8 months, 24 (69%) patients had recurrent syncope or presyncope events. Four (11%) patients were not capable of activating the ILR to save the event. A symptom‐rhythm correlation could be studied in 20 (83%) of 24 patients. Forty of 44 recurrences were captured by the ILR. There were 14 (40%) patients with at least one syncopal episode. An arrhythmic cause for syncope was found in eight of them (bradycardia in four and tachycardia in four). In the other six patients the heart rhythm was normal. In 17 (49%) patients with 1‐year follow‐up, the mean syncope event rate 12 months before ILR implantation was 4.7 ± 2.4, whereas the mean syncope event rate 12 months after ILR implantation was 1.3 ± 0.7 (P < 0.01). Resolution of symptoms was observed in 6 (17%) patients. These patients were significantly younger than patients without resolution (50 ± 18 vs 69 ± 14 years, p < 0.01) and five were women. Three (9%) patients died during follow‐up, all of them were noncompliant during their follow‐up. In conclusion, the ILR made symptom—rhythm correlation possible in 83% of patients with recurrent syncope. Syncope recurrences decreased significantly after implantation of the device, especially in the younger patients. Noncompliant patients had a high mortality rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2000.01532.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 86

Metadata

Authors
NIEROP, P. R., VAN MECHELEN, R., VAN ELSÄCKER, A., LUIJTEN, R. H. M., & ELHENDY, A.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2000-10
Volume
23
Issue
10
Pages
1532-1538
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2041709124
Cited by
86
References
1
FWCI
3.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders. https://app.cochat.ai/papers/10.1046/j.1460-9592.2000.01532.x
The paper
NIEROP, P. R., VAN MECHELEN, R., VAN ELSÄCKER, A., LUIJTEN, R. H. M., & ELHENDY, A. (2000). Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2000.01532.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.