Magnetocardiographic Intra‐QRS Fragmentation Analysis in the Identification of Patients with Sustained Ventricular Tachycardia after Myocardial Infarction
The DOI matches its Crossref record.
Abstract
KORHONEN, P., et al.: Magnetocardiographic Intra‐QRS Fragmentation Analysis in the Identification of Patients with Sustained Ventricular Tachycardia after Myocardial Infarction. The aim of this study was to investigate if magnetocardiographic (MCG) analysis of cardiac micropotentials within the QRS complex can identity patients prone to ventricular arrhythmias, and to compare it to MCG time‐domain, late‐field analysis. The study population consisted of 136 patients with remote MI, 53 with and 83 without a history of VT. After averaging and high pass filtering of multichannel MCG signals, time‐domain parameters describing the end‐QRS activity and fragmentation index M and score S describing the whole QRS complex were computed. Fragmentation and time‐domain parameters differed between the VT and control groups: fragmentation index M was 12 ± 3 versus 9 ± 2 (P < 0.001), fragmentation score S was 83 ± 42 versus 56 ± 21 (P < 0.001), and filtered QRS duration was 144 ± 32 versus 114 ± 19 ms (P < 0.001) in VT and control groups, respectively. A combination of fragmentation parameters yielded 87% sensitivity and 61% specificity in VT identification. Corresponding figures for a time‐domain parameter combination were 81% and 72%. Sensitivity of time‐domain analysis was 88% and specificity was 75% in a subgroup with anterior MI. In multivariate analysis, fragmentation and time‐domain analyses discriminated VT patients from controls independently of the extent of coronary artery disease or left ventricular dysfunction. MCG in postinfarction patients reveals pathology associated with propensity to ventricular arrhythmias inside and not only at the end of the QRS complex. MCG seems most accurate in the anterior infarct location.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
KORHONEN, P., HUSA, T., TIERALA, I., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00332.x · Cited by 51
Self-citationAssessing heart disease using a novel magnetocardiography device
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H. (2021) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abe5c5 · Cited by 18
Metadata
- Authors
- KORHONEN, P., MONTONEN, J., ENDT, P., MÄKIJÄRVI, M., TRAHMS, L., KATILA, T., & TOIVONEN, L.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 24
- Issue
- 8
- Pages
- 1179-1186
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2043496860
- Cited by
- 28
- References
- 0
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetocardiographic Intra‐QRS Fragmentation Analysis in the Identification of Patients with Sustained Ventricular Tachycardia after Myocardial Infarction. https://app.cochat.ai/papers/10.1046/j.1460-9592.2001.01179.x
- The paper
- KORHONEN, P., MONTONEN, J., ENDT, P., MÄKIJÄRVI, M., TRAHMS, L., KATILA, T., & TOIVONEN, L. (2001). Magnetocardiographic Intra‐QRS Fragmentation Analysis in the Identification of Patients with Sustained Ventricular Tachycardia after Myocardial Infarction. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2001.01179.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.