Increased intra-QRS fragmentation in magnetocardiography as a predictor of arrhythmic events and mortality in patients with cardiac dysfunction after myocardial infarction
Open accessAbstract
Introduction: Increased intra‐QRS fragmentation score (FRA) in magnetocardiography (MCG) has shown association with sustained ventricular arrhythmias in post‐MI patients suggesting its relation to arrhythmia substrate. The aim of this study was to investigate whether increased FRA in MCG predicts arrhythmic events and mortality after acute myocardial infarction (MI) with cardiac dysfunction. Methods and Results: A series of 158 patients with acute MI and left ventricular ejection fraction (LVEF) <50% were studied. Their age was 60 ± 10 years and LVEF 40 ± 6%. MCG was registered and FRA was computed. For comparison, QRS duration in 12‐lead ECG was measured. In a mean follow‐up of 50 ± 15 months, 32 (20%) patients died and 18 (11%) had an arrhythmic event. Both arrhythmic event rate and all‐cause mortality were significantly higher in patients with increased FRA (P < 0.001 for both). In contrast, increased QRS duration in ECG predicted all‐cause mortality (P < 0.05) but not arrhythmic events. In multivariate analysis, FRA was an independent predictor of both arrhythmic events and all‐cause mortality. Using a combined criterion of increased FRA and LVEF < 30% yielded positive and negative predictive accuracies of 50% and 91% for arrhythmic events. Conclusion: In post‐MI patients with left ventricular dysfunction, increased intra‐QRS fragmentation in high‐resolution magnetocardiography predicts arrhythmic events, whereas QRS duration in 12‐lead ECG predicts all‐cause mortality. Analysis of intra‐QRS fragmentation by MCG may assist in guiding therapy of post‐MI patients, for example, by selecting those who would benefit most from prophylactic implantable cardioverter‐defibrillator therapy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885 · see citing works
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165 · see citing works
Cohn, J. N., Johnson, G., Ziesche, S., Cobb, F., Francis, G., Tristani, F., Smith, R., Dunkman, W. B., Loeb, H., Wong, M., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250502 · Cited by 2,833 · see citing works
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,026 · see citing works
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519 · see citing works
Sudden Death Due to Cardiac Arrhythmias
Huikuri, H. V., Castellanos, A., & Myerburg, R. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmra000650 · Cited by 1,476 · see citing works
Bigger, J. T. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372201 · Cited by 1,007 · see citing works
Buxton, A. E., Lee, K. L., DiCarlo, L. A., Gold, M. R., Greer, G. S., Prystowsky, E. N., O’Toole, M. F., TANG, A. S. L., Fisher, J. D., Coromilas, J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200006293422602 · Cited by 564 · see citing works
Frequency of Sudden Cardiac Death and Profiles of Risk
Myerburg, R. J., Interian, A., Mitrani, R. D., Kessler, K. M., & Castellanos, A. W. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00477-3 · Cited by 436 · see citing works
Bloomfield, D. M., Steinman, R. C., Namerow, P. B., Parides, M. K., Davidenko, J. M., Kaufman, E. S., Shinn, T., Curtis, A. B., Fontaine, J. M., Holmes, D., et al. (2004) · Circulation · doi:10.1161/01.cir.0000143160.14610.53 · Cited by 339 · see citing works
Adverse Events With Transvenous Implantable Cardioverter-Defibrillators
Rosenqvist, M., Beyer, T., Block, M. S., den Dulk, K., Minten, J., & Lindemans, F. W. (1998) · Circulation · doi:10.1161/01.cir.98.7.663 · Cited by 231 · see citing works
T-wave alternans as a predictor for sudden cardiac death after myocardial infarction
Ikeda, T., Saito, H., Tanno, K., Shimizu, H., Watanabe, J., Ohnishi, Y., Kasamaki, Y., & Ozawa, Y. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02171-3 · Cited by 225 · see citing works
Recalls and Safety Alerts Involving Pacemakers and Implantable Cardioverter-Defibrillator Generators
Maisel, W. H. (2001) · JAMA · doi:10.1001/jama.286.7.793 · Cited by 210 · see citing works
ZIMETBAUM, P. J., Buxton, A. E., Batsford, W. P., Fisher, J. D., Hafley, G. E., Lee, K. L., O’Toole, M. F., Page, R. L., Reynolds, M. R., & Josephson, M. E. (2004) · Circulation · doi:10.1161/01.cir.0000139311.32278.32 · Cited by 186 · see citing works
Prediction of Sudden Cardiac Death
Huikuri, H. V., Mäkikallio, T. H., Raatikainen, M. J. P., Perkiömäki, J. S., Castellanos, A., & Myerburg, R. J. (2003) · Circulation · doi:10.1161/01.cir.0000077519.18416.43 · Cited by 177 · see citing works
Tapanainen, J. M., Still, A.-M., Airaksinen, J. K. E., & Huikuri, H. V. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00645.x · Cited by 141 · see citing works
QRS duration: a simple marker for predicting cardiac mortality in ICD patients with heart failure
Bode-Schnurbus, L., Böcker, D., Block, M., Gradaus, R., Heinecke, A., Breithardt, G., & Borggrefe, M. (2003) · Heart · doi:10.1136/heart.89.10.1157 · Cited by 114 · see citing works
Quantitative analysis of myocardial infarct structure in patients with ventricular tachycardia.
Bolick, D. R., Hackel, D. B., Reimer, K. A., & Ideker, R. E. (1986) · Circulation · doi:10.1161/01.cir.74.6.1266 · Cited by 113 · see citing works
Shamim, W., Yousufuddin, M., Cicoria, M., Gibson, D. G., Coats, A. J. S., & Henein, M. Y. (2002) · Heart · doi:10.1136/heart.88.1.47 · Cited by 105 · see citing works
Mechanisms Precipitating Acute Cardiac Events
Muller, J. E., Kaufmann, P. G., Luepker, R. V., Weisfeldt, M. L., DEEDWANIA, P. C., & Willerson, J. T. (1997) · Circulation · doi:10.1161/01.cir.96.9.3233 · Cited by 104 · see citing works
Hood, M., Pogwizd, S. M., Peirick, J., & Cain, M. E. (1992) · Circulation · doi:10.1161/01.cir.86.6.1888 · Cited by 66 · see citing works
Analysis of Abnormal Intra-QRS Potentials
Lander, P., Gomis, P., Goyal, R., Berbari, E. J., Caminal, P., Lazzara, R., & Steinberg, J. S. (1997) · Circulation · doi:10.1161/01.cir.95.6.1386 · Cited by 57 · see citing works
Korhonen, P., MOINTONEN, J., MÄKINÄRVI, M., Katila, T. E., Nieminen, M. S., & Toivonen, L. K. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00336.x · Cited by 43 · see citing works
Self-citationMäkijärvi, M. A., Montonen, J., Toivonen, L. K., SILTANEN, P., Nieminen, M. S., Leiniö, M., & Katila, T. E. (1993) · Journal of Electrocardiology · doi:10.1016/0022-0736(93)90003-v · Cited by 36 · see citing works
Self-citationMERIT-HF mortality and morbidity data
Hjalmarson, X. C., & Fagerberg, B. (2000) · Basic Research in Cardiology · doi:10.1007/s003950070017 · Cited by 35 · see citing works
Müller, H.-P., Gödde, P., Czerski, K., Oeff, M., Agrawal, R., ENDT, P., Kruse, W., Steinhoff, U., & Trahms, L. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/1/009 · Cited by 30 · see citing works
Korhonen, P., Montonen, J., ENDT, P., Mäkijärvi, M. A., Trahms, L., Katila, T. E., & Toivonen, L. K. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.01179.x · Cited by 28 · see citing works
Self-citationMADIT-II: Substudies and Their Implications
Moss, A. J. (2003) · Cardiac Electrophysiology Review · doi:10.1023/b:cepr.0000023155.60684.91 · Cited by 24 · see citing works
Magnetocardiographic Functional Imaging Studies in the BioMag Laboratory
Montonen, J., Ahonen, A., Hämäläinen, M., Ilmoniemi, R. J., Laine, P., Nenonen, J. T., Paavola, M., Simelius, K., Simola, J., & Katila, T. E. (2000) · Springer eBooks · doi:10.1007/978-1-4612-1260-7_121 · Cited by 21 · see citing works
Self-citationCleland, J. G. F., Erhardt, L., Hall, A. S., Winter, C., & Ball, S. G. (1993) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199312002-00006 · Cited by 19 · see citing works
Korhonen, P., PESOLA, K., Järvinen, A., Mäkijärvi, M. A., Katila, T. E., & Toivonen, L. K. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01339.x · Cited by 14 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 2
- Montonen J, Katila T, Leiniö M, Madekivi S, Mäkijärvi M, Nenonen J, Siltanen P. Time and frequency domain analyses of cardiac microp- otentials In: Atsumi K, Kotani M, Ueno S, Katila T, Williamson SJ, eds. Biomagnetism '87. Tokyo: Denki University Press, 1988, pp. 278- 281.
- Van Leeuwen P, Haupt C, Hoormann C, Hailer B, Mackert BM, Stroink G. A 67-channel biomagnetometer designed for cardiology and other applications In: Yoshimoto T, Kotani M, Kuriki S, Karibe H, Nakasato N, eds. Recent Advances in Biomagnetism. Sendai: Tohoku University Press, 1999, pp. 89-92.
Cited by
Sorted by citations
Fragmented QRS: A predictor of mortality and sudden cardiac death
Das, M. K., & Zipes, D. P. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.019 · Cited by 241 · see citing works
Fragmented QRS: What Is The Meaning?
Take, Y., & Morita, H. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30544-7 · Cited by 111 · see citing works
“Magnetoelectrocardiography is a possible method to evaluate qualitative analysis of fQRS, but it cannot be used as a routine examination [40].”
MethodKwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103 · see citing works
“comparative study with ECG-QRSd [73].”
Das, M. K., & Masry, H. E. (2009) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e328333d35d · Cited by 87 · see citing works
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 71 · see citing works
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 57 · see citing works
“Riccardo Fenici and his colleagues have reviewed the medical applications of magnetocardiography [36], including diagnosing myocardial ischemia [23], assessing the risk of an arrhythmia [37], imaging of arrhythmogenic mechanisms, measuring the fetal heartbeat [38], and possibly even detecting left ventricular overload…”
BackgroundOptical multichannel room temperature magnetic field imaging system for clinical application
Lembke, G., Erne, S. N., Nowak, H., Menhorn, B., Pasquarelli, A., & Bison, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000876 · Cited by 53 · see citing works
Shin, E., Lam, Y., Her, A., Brachmann, J., Jung, F., & Park, J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.165 · Cited by 38 · see citing works
A Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses
Zhu, K., & Kiourti, A. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3186643 · Cited by 35 · see citing works
“MCG features that can be extracted for arrhythmogenic risk evaluation include the late field, intra-QRS fragmentation, and QT dispersion (QTd) [113] [118]-[120].”
BackgroundMethodA portable diagnostic device for cardiac magnetic field mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/015008 · Cited by 39 · see citing works
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29 · see citing works
“With this method the extrema of fragmented electrical activity during the plateau phase of the action potential that exceed noise level are counted [7, 25].”
InfluentialKawakami, S., Takaki, H., Hashimoto, S., Kimura, Y., Nakashima, T., Aiba, T., KUSANO, K. F., Kamakura, S., Yasuda, S., & Sugimachi, M. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0683 · Cited by 27 · see citing works
Sudden cardiac death: The role of imaging
van der Bijl, P., Delgado, V., & Bax, J. J. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.03.010 · Cited by 23 · see citing works
“006) in a study of 158 postinfarct patients [14].”
BackgroundWang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 23 · see citing works
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 23 · see citing works
Forleo, G. B., Rocca, D. G. D., Papavasileiou, L. P., Panattoni, G., Sergi, D., Duro, L., Mahfouz, K., Magliano, G., Santini, L., & Romeo, F. (2011) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e32834ae458 · Cited by 21 · see citing works
Lee, Y. H., Yu, K. K., Kim, J. M., Kwon, H.-C., & Kim, K. (2009) · Superconductor Science and Technology · doi:10.1088/0953-2048/22/11/114003 · Cited by 20 · see citing works
Forty Years of Magnetocardiology
Stroink, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_1 · Cited by 19 · see citing works
“In a later study [51], involving 158 patients with acute MI with left ventricular dysfunction they showed that increased QRS fragmentation over the QRS interval predicts arrhythmic events and mortality in such post-MI patients.”
BackgroundBang, W.-D., Kim, K., Lee, Y.-H., Kwon, H., Park, Y., Pak, H.-N., Ko, Y.-G., Lee, M., & Joung, B. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1339 · Cited by 17 · see citing works
“Increased intra-QRS fragmentation in MCG predicts arrhythmic events, especially ventricular tachycardia and mortality in post-MI patients with left ventricular dysfunction.(12,13) Moreover, MCG has been reported to show higher non-dipolar structures on cardiac MF maps after ST-elevation and non-ST-elevation myocardial…”
BackgroundLachlan, T., He, H., Sharma, K., Khan, J. N., Rajappan, K., Morley‐Davies, A., Patwala, A., Randeva, H. S., & Osman, F. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-038804 · Cited by 12 · see citing works
Magnetocardiography in the Evaluation of Sudden Cardiac Death Risk: A Systematic Review
Lachlan, T., He, H., KUSANO, K. F., Aiba, T., Brisinda, D., Fenici, R., & Osman, F. (2024) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.70028 · Cited by 7 · see citing works
“Two studies conducted multivariate analysis, identifying fragmentation as an independent discriminator for VA even after adjusting for LVEF or LV aneurysm presence (Korhonen, Montonen, et al. 2001; Korhonen et al. 2006b).”
BackgroundMethodMäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_44 · Cited by 7 · see citing works
Self-citationQuan, W., Lu, G.-P., Qi, W.-H., Li, Y., Shen, Y., & Rong, Y. U. A. N. (2008) · Chinese Medical Journal · doi:10.1097/00029330-200801010-00005 · Cited by 7 · see citing works
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100514 · Cited by 7 · see citing works
Cardiac signal extraction in patients with Implantable Cardioverter Defibrillators
Paolo, D. D. P., Mueller, H., Goernig, M., Haueisen, J., & Erne, S. N. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.07.004 · Cited by 6 · see citing works
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6 · see citing works
Kesavaraja, C., Sengottuvel, S., Patel, R., & Mani, A. (2024) · Circuits Systems and Signal Processing · doi:10.1007/s00034-024-02655-9 · Cited by 5 · see citing works
“9, where there is a minor bifurcation in the QRS deflection associated with abnormal electrical activity [22, 26].”
Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization
Veen, B. D. V., Stenroos, M., & Wakai, R. T. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3524374 · Cited by 4 · see citing works
“Manyimportant clinical applications of MCG, such as diagnosis of coronary artery disease [15], [16] and risk assessment for ventricular tachycardia [17], utilize sensor space analysis of magnetic field maps.”
Lachlan, T., He, H., Miller, A., Chandan, N., Siddiqui, S., Beadle, R. M., Wilson, D. G., Petkar, S., Randeva, H. S., & Osman, F. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.12.020 · Cited by 4 · see citing works
Goernig, M., DiPietroPaolo, D., Haueisen, J., & Erne, S. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_2 · Cited by 4 · see citing works
Kleemann, T., Kouraki, K., Strauss, M., Skarlos, A., Zeymer, U., & Zahn, R. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9754-6 · Cited by 4 · see citing works
“In these patients increased intra-QRS fragmentation in highresolution magnetocardiography anticipated arrhythmic events, whereas QRS duration in 12-lead ECG-predicted all-cause mortality [15].”
BackgroundInfluentialMagnetocardiography Throws Its Hat in the Ring
Steinberg, J. S., & Levitt, H. L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00418.x · Cited by 4 · see citing works
Special article Magnetocardiography in clinical cardiology. Status quo and future applications
Leithäuser, B., Jung, F., & Park, J. (2011) · Advances in Interventional Cardiology · doi:10.5114/pwki.2011.24739 · Cited by 4 · see citing works
Grenzen und Möglichkeiten der nichtinvasiven Risikostratifikation für den plötzlichen Herztod
Tönnis, T., & Kück, K. (2009) · Herz · doi:10.1007/s00059-009-3290-x · Cited by 4 · see citing works
Liu, L., Pan, Y., Gao, H., Jin, Y., Feng, L., Ma, Z., Zhang, H., Yang, S., Wu, T., Zhang, M., et al. (2025) · JACC Advances · doi:10.1016/j.jacadv.2025.102073 · Cited by 3 · see citing works
Surface Mapping and Magnetoelectrocardiography
Yamada, S. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_26 · Cited by 3 · see citing works
Detection of U wave activity in healthy volunteers by high-resolution magnetocardiography
Goernig, M., Haueisen, J., Liehr, M., Schlosser, M., Figulla, H. R., & LEDER, U. (2009) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2009.06.004 · Cited by 3 · see citing works
Localization of prior myocardial infarction by repolarization variables
Vesterinen, P., Väänänen, H., Stenroos, M., Hänninen, H., Korhonen, P., Tierala, I., Husa, T., Mäkijärvi, M. A., & Toivonen, L. K. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.12.029 · Cited by 3 · see citing works
Self-citationStrauss, M., Kouraki, K., Skarlos, A., Zahn, R., & Kleemann, T. (2013) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-013-0264-8 · Cited by 2 · see citing works
Superconducting Quantum Interference (SQUIDs)
Fagaly, R. L., Krause, H., Mück, M., Tanaka, S., Nowak, H., Stolz, R., Kirtley, J. R., Schurig, T., Beyer, J., McDermott, R., et al. (2015) · Applied Superconductivity · doi:10.1002/9783527670635.ch9 · Cited by 2 · see citing works
Vesterinen, P. (2007) · Työväentutkimus Vuosikirja · Cited by 2 · see citing works
Atrial Electric Signal During Sinus Rhythm in Lone Paroxysmal Atrial Fibrillation
Jurkko, R. (2009) · Työväentutkimus Vuosikirja · Cited by 2 · see citing works
Vesterinen, P., Väänänen, H., Hänninen, H., Korhonen, P., Tierala, I., Husa, T., Mäkijärvi, M. A., & Toivonen, L. K. (2007) · Cardiology · doi:10.1159/000107784 · Cited by 1 · see citing works
Self-citationICDs and Risk Stratification in Magnetic Field Imaging
Paolo, D. D. P., Toennis, T., & Nicola, S. (2011) · InTech eBooks · doi:10.5772/21948 · Cited by 1 · see citing works
“(Korhonen et al., 2006) have performed a pioneer clinical study analyzing the intra QRS-fragmentation in averaged MCG/MFI data (for a mathematical description of the method refers to (Link et al.”
BackgroundMethodInfluentialNowak, H. (2015) · digital Encyclopedia of Applied Physics · doi:10.1002/3527600434.eap761 · Cited by 1 · see citing works
Anwendung der Magnetokardiographie in der klinischen Kardiologie
Leithäuser, B., Jung, F., & Park, J. W. (2012) · Der Kardiologe · doi:10.1007/s12181-012-0401-3
A Portable Diagnostic Device for Cardiac Magnetic Field Mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2016) · White Rose Research Online (University of Leeds, The University of Sheffield, University of York) · doi:10.48550/arxiv.1609.05771
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2011) · Springer eBooks · doi:10.1007/978-0-85729-880-5_12
Self-citationSurface Mapping and Magneto-Electrocardiography
Yamada, S., & Kandori, A. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4978-1_14
Magnetocardiography can detect ventricular arrhythmia after myocardial ischemiaPreprint
Arekhloo, N. G., Parvizi, H., Mardani, M., Sularz, A., Alkhouli, M. A., Heidari, H., & Nazarpour, K. (2025) · medRxiv · doi:10.1101/2025.11.04.25339469
“All reported higher fragmentation scores in patients with VTAs compared to those without, highlighting its potential as a predictive marker for post-MI VTAs [9, 21-23, 26, 27, 30].”
- Authors
- KORHONEN, P., HUSA, T., TIERALA, I., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L.
- Affiliations
- Helsinki University Hospital (FI)
- Corresponding author
- KORHONEN, PETRI
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-11-29
- Volume
- 17
- Issue
- 4
- Pages
- 396-401
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2083743713
- Cited by
- 51
- References
- 31
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 3 · 2022: 3 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 1 · 2013: 3 · 2012: 3
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- magnetocardiography, acute myocardial infarction, left ventricular dysfunction, ventricular arrhythmias, all-cause mortality, QRS duration, implantable cardioverter-defibrillator, arrhythmia prediction, left ventricular ejection fraction
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Follow-Up Studies, Heart Rate, Humans, Magnetics, Middle Aged, Myocardial Infarction, Prognosis, Prospective Studies, Risk Factors, Stroke Volume, Time Factors, Survival Rate, Ventricular Dysfunction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review