Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Assessing heart disease using a novel magnetocardiography device

Open access
Beadle, R, McDonnell, D, Ghasemi-Roudsari, S, Unitt, L, Parker, S J, Varcoe, B T H · 2021 · Biomedical Physics & Engineering Express

Abstract

The aim of this paper is to present the use of a portable, unshielded magnetocardiograph (MCG) and identify key characteristics of MCG scans that could be used in future studies to identify parameters that are sensitive to cardiac pathology. We recruited 50 patients with confirmed myocardial infarction (MI) within the past 12 weeks and 46 volunteers with no history of cardiac disease. A set of 38 parameters were extracted from MCG features including both signals from the sensor array and from magnetic images obtained from the device and principal component analysis was used to concentrate the information contained in these parameters into uncorrelated predictors. Linear fits of these parameters were then used to examine the ability of MCG to distinguish between sub-groups of patients. In the first instance, the primary aim of this study was to ensure that MCG has a basic ability to separate a highly polarised patient group (young controls from post infarction patients) and to identify parameters that could be used in future studies to build a formal diagnostic tool kit. Parameters that parameterised left ventricular ejection fraction (LVEF) were identified and an example is presented to show differential low and high ejection fractions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/2057-1976/abe5c5

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Thecolour map is a representation of the magnetic fi eld detected by the sensors in the array. The outer ring of sensors is disabled for this view. A vector is drawn between the maximum and minimum magnetic fi eld Zmax and Zmin respectively. Grey dots in in the center of the image show the position of sensor. Grey dots in the outer boundary represent part of the image reconstruction map.
Figure 1 Thecolour map is a representation of the magnetic fi eld detected by the sensors in the array. The outer ring of sensors is disabled for this view. A vector is drawn between the maximum and minimum magnetic fi eld Zmax and Zmin respectively. Grey dots in in the center of the image show the position of sensor. Grey dots in the outer boundary represent part of the image reconstruction map.CC-BY · From the PDF
Figure 2 Theindividual traces from the 19 sensor coils in the array overlaid with a concurrent ECG ( black ) . The central region highlights the focal region for parameter extraction.
Figure 2 Theindividual traces from the 19 sensor coils in the array overlaid with a concurrent ECG ( black ) . The central region highlights the focal region for parameter extraction.CC-BY · From the PDF
Figure 3 The fi gure on the left shows the distribution of the PC1 based probability score versus patient number for post MI and YHC patients. The fi gure on the right shows the ROC curve obtained for this distribution. The AUC is 95% and for a cut point of 0.57 the Sensitivity and Speci fi city of 100% ( 95%CI:92.89%to100.00% ) and76% ( 95%CI:58.87%to85.73% ) respectively.
Figure 3 The fi gure on the left shows the distribution of the PC1 based probability score versus patient number for post MI and YHC patients. The fi gure on the right shows the ROC curve obtained for this distribution. The AUC is 95% and for a cut point of 0.57 the Sensitivity and Speci fi city of 100% ( 95%CI:92.89%to100.00% ) and76% ( 95%CI:58.87%to85.73% ) respectively.CC-BY · From the PDF
Figure 4 MCGmodelofLVEFversusclinical determination. The four regions are: ( 1 ) in Red, Mischaracterisation error, reducing patient risk; ( 2 ) , and ( 3 ) , in Green, patient accurately characterised; ( 4 ) in Blue, Patient mischaracterised as higher risk. The dotted line indicates the curve y = x. Error bars for clinical evaluation are ± 10%andthestatistical standard deviation of the MCG measurement.
Figure 4 MCGmodelofLVEFversusclinical determination. The four regions are: ( 1 ) in Red, Mischaracterisation error, reducing patient risk; ( 2 ) , and ( 3 ) , in Green, patient accurately characterised; ( 4 ) in Blue, Patient mischaracterised as higher risk. The dotted line indicates the curve y = x. Error bars for clinical evaluation are ± 10%andthestatistical standard deviation of the MCG measurement.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Research works printed but not linked: 4

  1. Kawakami, 2012, Fragmented left ventricular activation on magnetocardiography can predict adverse cardiac events in dilated cardiomyopathy patients with narrow QRS duration, Circulation, 126, A12431, 10.1161/circ.126.suppl_21.A12431 · doi:10.1161/circ.126.suppl_21.a12431
  2. Daniel, 2012, Characterization of ventricular depolarization and repolarization changes in a porcine model of myocardial infarction, Physiol. Meas., 33, 1975, 10.1088/0967-3334/33/12/1975 · DOI
  3. Anthony, 2017, Cost-Effectiveness of Cardiotoxicity Monitoring.
  4. Camm, 2019, Clinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia, Journal of Electrocardiology, 57, 10, 10.1016/j.jelectrocard.2019.07.009 · DOI · Paper page

Cited by

See all 18

Metadata

Authors
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H.
Affiliations
  • South Warwickshire NHS Foundation Trust (GB)
  • Creavo (United Kingdom) (GB)
  • University of Leeds (GB)
Corresponding author
Varcoe, B T H
Venue
Biomedical Physics & Engineering Express
Published
2021-02-23
Volume
7
Issue
2
Pages
025018
ISSN
2057-1976 (ISSN-L)
OpenAlex
W3128337053
Cited by
18
References
35
Citations by year
2026: 3 · 2025: 6 · 2024: 4 · 2023: 4 · 2022: 1
FWCI
1.52
Type
journal article
Language
en
Open access
Licence
Locations
  • Biomedical Physics & Engineering Express (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
magnetocardiography, myocardial infarction, heart disease diagnosis, left ventricular ejection fraction, principal component analysis, diagnostic biomarkers
MeSH terms
Heart Diseases, Humans, Myocardial Infarction, Stroke Volume, Ventricular Function, Left, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing heart disease using a novel magnetocardiography device. https://app.cochat.ai/papers/10.1088/2057-1976/abe5c5
The paper
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H. (2021). Assessing heart disease using a novel magnetocardiography device. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/abe5c5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.