CoChat

Relation Between the Pacing Induced Sequence of Activation and Left Ventricular Pump Function in Animals

PRINZEN, FRITS W., PESCHAR, MAAIKE · 2002 · Pacing and Clinical Electrophysiology
Cited by 286

The DOI matches its Crossref record.

Abstract

PRINZEN, F.W., et al.: Relation Between the Pacing Induced Sequence of Activation and Left Ventricu‐lar Pump Function in Animals. The main goal of this article was to review animal experimental work on the effect of asynchronous activation on ventricular pump function. During normal sinus rhythm and atrial pacing, the Purkinje system contributes significantly to the rapid electrical activation of the ventricles. In contrast, during ventricular pacing the impulse is almost exclusively conducted through the normal myocardium. As a consequence, electrical activation of the ventricles becomes asynchronous and has an abnormal sequence. The abnormal impulse conduction causes considerable disturbances to occur in regional systolic fiber shortening, mechanical work, blood flow, and oxygen consumption; low values occurring in early activated regions and values above normal being present in late activated regions. Many animal studies have now shown that the abnormal electrical activation, induced by ventricular pacing, leads to a depression of systolic and diastolic LV function. Pacing at the right ventricular apex (the conventional pacing site) reduces LV function more than pacing at the high ventricular septum or at LV sites. In canine hearts with experimental LBBB, LV pacing significantly improves LV pump function. Differences in LV pump function between (combinations of) pacing sites are poorly correlated with QRS duration. Therefore, the cause of the depression of LV function during abnormal electrical activation appears to be a combination of the asynchrony and the sequence of activation. These experimental findings justify continuing attention for optimizing the site(s) of ventricular pacing in patients with normal and abnormal ventricular impulse conduction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2002.00484.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
PRINZEN, F. W., & PESCHAR, M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2002-04
Volume
25
Issue
4
Pages
484-498
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2059523482
Cited by
286
References
0
FWCI
5.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.