Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Background: Near‐infrared spectroscopy is a developing technique for monitoring cerebral oxygenation during anaesthesia. The aim of this study was to evaluate absolute values of cerebral oxygenation during stable anaesthesia conditions in otherwise healthy children using the recently introduced INVOS 5100 cerebral oximeter with a paediatric and adult sensor and to compare them with values obtained from the NIRO 300 oximeter. Methods: Thirty paediatric surgical patients (aged 0.23–15.97 years) were studied during general anaesthesia with tracheal intubation and controlled ventilation. Comparative measurements of cerebral oxygenation were performed on the forehead with two probes within 10 min under stable cardiorespiratory and anaesthesia conditions. Cerebral oxygenation values (rSO 2) obtained from the paediatric and adult INVOS 5100 sensors were compared with the tissue oxygenation index (TOI) obtained from the NIRO 300 cerebral oximeter using 4‐ and 5‐cm emitter‐detector separation. Results: Cerebral rSO 2 values and the TOI values both showed a large range of cerebral oxygenation in the children studied (rSO 2: 59–95%, TOI: 48–85%). Cerebral rSO 2 values measured by the INVOS 5100, particularly with the paediatric sensor, were significantly higher than the TOI values obtained from the NIRO 300 (P < 0.0001). Agreement between the INVOS and NIRO oximeter was poor. Conclusion: The large range and the poor agreement of cerebral oxygenation values between the two oximeters makes it difficult to define a normal value. Cerebral oxygenation readings by these monitors, based on one single point measurement during anaesthesia, should be viewed with caution. Actually, there may be little indication for routine use of such monitoring during general anaesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Cited by
Hyttel-Sorensen, S., Pellicer, A., Alderliesten, T., Austin, T., van Bel, F., Benders, M., Claris, O., Dempsey, E., Franz, A. R., Fumagalli, M., et al. (2015) · BMJ · doi:10.1136/bmj.g7635 · Cited by 309
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01488.x · Cited by 269
Lemmers, P. M. A., Toet, M. C., & van Bel, F. (2008) · Pediatrics · doi:10.1542/peds.2007-0925 · Cited by 244
Neurological Monitoring for Congenital Heart Surgery
Andropoulos, D. B., Stayer, S. A., Diaz, L. K., & Ramamoorthy, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000134808.52676.4d · Cited by 163
“The pediatric model (INVOS 5100) is designed for patients weighing 4–40 kg and uses a different algorithm that takes into account the thinner skull and extracranial tissues of infants and children (32).”
Comparison of tissue oximeters on a liquid phantom with adjustable optical properties
Kleiser, S., Nasseri, N., Andresen, B., Greisen, G., & Wolf, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.002973 · Cited by 103
Metadata
- Authors
- Dullenkopf, A., Frey, B., Baenziger, O., Gerber, A., & Weiss, M.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2003-06
- Volume
- 13
- Issue
- 5
- Pages
- 384-391
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2086325155
- Cited by
- 127
- References
- 2
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.