A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
Abstract
Summary: Background : Near‐infrared spectroscopy (NIRS) is a noninvasive optical monitor of regional cerebral oxygen saturation (rSO 2). The aim of this study was to validate the use of NIRS by cerebral oximetry in estimating invasively measured mixed venous oxygen saturation (SvO 2) in pediatric postoperative cardiac surgery patients. Methods : Twenty patients were enrolled following cardiac surgery with intraoperative placement of a pulmonary artery (PA) or superior vena cava (SVC) catheter. Five patients underwent complete biventricular repair – complete atrioventricular canal (n = 3) and other (n = 2). Fifteen patients with functional single ventricle underwent palliative procedures – bidirectional Glenn (n = 11) and Fontan (n = 4). Cerebral rSO 2 was monitored via NIRS (INVOS 5100) during cardiac surgery and 6 h postoperatively. SvO 2 was measured from blood samples obtained via an indwelling PA or SVC catheter and simultaneously correlated with rSO 2 by NIRS at five time periods: in the operating room after weaning from cardiopulmonary bypass, after sternal closure, and in the CICU at 2, 4, and 6 h after admission. Results : Each patient had five measurements (total = 100 comparisons). SvO 2 obtained via an indwelling PA or SVC catheter for all patients correlated with rSO 2 obtained via NIRS: Pearson's correlation coefficient of 0.67 (P < 0.0001) and linear regression of r2 = 0.45 (P < 0.0001). Separate linear regression of the complete biventricular repairs demonstrated an r = 0.71, r2 = 0.50 (P < 0.0001). Bland–Altman analysis showed a bias of +3.3% with a precision of 16.6% for rSO 2 as a predictor of SvO 2 for all patients. Cerebral rSO 2 was a more accurate predictor of SvO 2 in the biventricular repair patients (bias −0.3, precision 11.8%), compared with the bidirectional Glenn and Fontan patients. Conclusions : Regional cerebral oximetry via NIRS correlates with SvO 2 obtained via invasive monitoring. However, the wide limits of agreement suggest that it may not be possible to predict absolute values of SvO 2 for any given patient based solely on the noninvasive measurement of rSO 2. Near‐infrared spectroscopy, using the INVOS 5100 cerebral oximeter, could potentially be used to indicate trends in SVO 2, but more studies needs to be performed under varying clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Calculating correlation coefficients with repeated observations: Part 2—correlation between subjects
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6980.633 · Cited by 1,082
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6977.446 · Cited by 1,034
Tweddell, J. S., Hoffman, G. M., & Mussatto, K. A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)01082-6 · Cited by 462
Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00012 · Cited by 451
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I. (1991) · Critical Care Medicine · doi:10.1097/00003246-199101000-00020 · Cited by 322
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
Cited by
Ranucci, M., Isgrò, G., Carlucci, C., De La Torre, T., Enginoli, S., Frigiola, A., & Surgical and Clinical Outcome REsearch (SCORE) Group (2010) · Critical Care · doi:10.1186/cc9217 · Cited by 100
Metadata
- Authors
- TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2005-05-23
- Volume
- 15
- Issue
- 6
- Pages
- 495-503
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2072864447
- Cited by
- 269
- References
- 25
- FWCI
- 11.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. https://app.cochat.ai/papers/10.1111/j.1460-9592.2005.01488.x
- The paper
- TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005). A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Pediatric Anesthesia. https://doi.org/10.1111/j.1460-9592.2005.01488.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.