Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 269

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients

TORTORIELLO, TIA A., STAYER, STEPHEN A., MOTT, ANTONIO R., DEAN McKENZIE, E., FRASER, CHARLES D., ANDROPOULOS, DEAN B., CHANG, ANTHONY C.·2005·Pediatric Anesthesia

Abstract

Summary: Background : Near‐infrared spectroscopy (NIRS) is a noninvasive optical monitor of regional cerebral oxygen saturation (rSO 2). The aim of this study was to validate the use of NIRS by cerebral oximetry in estimating invasively measured mixed venous oxygen saturation (SvO 2) in pediatric postoperative cardiac surgery patients. Methods : Twenty patients were enrolled following cardiac surgery with intraoperative placement of a pulmonary artery (PA) or superior vena cava (SVC) catheter. Five patients underwent complete biventricular repair – complete atrioventricular canal (n = 3) and other (n = 2). Fifteen patients with functional single ventricle underwent palliative procedures – bidirectional Glenn (n = 11) and Fontan (n = 4). Cerebral rSO 2 was monitored via NIRS (INVOS 5100) during cardiac surgery and 6 h postoperatively. SvO 2 was measured from blood samples obtained via an indwelling PA or SVC catheter and simultaneously correlated with rSO 2 by NIRS at five time periods: in the operating room after weaning from cardiopulmonary bypass, after sternal closure, and in the CICU at 2, 4, and 6 h after admission. Results : Each patient had five measurements (total = 100 comparisons). SvO 2 obtained via an indwelling PA or SVC catheter for all patients correlated with rSO 2 obtained via NIRS: Pearson's correlation coefficient of 0.67 (P < 0.0001) and linear regression of r2 = 0.45 (P < 0.0001). Separate linear regression of the complete biventricular repairs demonstrated an r = 0.71, r2 = 0.50 (P < 0.0001). Bland–Altman analysis showed a bias of +3.3% with a precision of 16.6% for rSO 2 as a predictor of SvO 2 for all patients. Cerebral rSO 2 was a more accurate predictor of SvO 2 in the biventricular repair patients (bias −0.3, precision 11.8%), compared with the bidirectional Glenn and Fontan patients. Conclusions : Regional cerebral oximetry via NIRS correlates with SvO 2 obtained via invasive monitoring. However, the wide limits of agreement suggest that it may not be possible to predict absolute values of SvO 2 for any given patient based solely on the noninvasive measurement of rSO 2. Near‐infrared spectroscopy, using the INVOS 5100 cerebral oximeter, could potentially be used to indicate trends in SVO 2, but more studies needs to be performed under varying clinical conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1460-9592.2005.01488.x

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 269

Metadata

Authors
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C.
Venue
Pediatric Anesthesia
Publisher
Wiley
Published
2005-05-23
Volume
15
Issue
6
Pages
495-503
ISSN
  • 1155-5645 (ISSN-L)
  • 1460-9592
OpenAlex
W2072864447
Cited by
269
References
25
FWCI
11.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. https://app.cochat.ai/papers/10.1111/j.1460-9592.2005.01488.x
The paper
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005). A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Pediatric Anesthesia. https://doi.org/10.1111/j.1460-9592.2005.01488.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.