Neurological Monitoring for Congenital Heart Surgery
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
In Brief The incidence of neurological complications after pediatric cardiac surgery ranges from 2% to 25%. The causes are multifactorial and include preoperative brain malformations, perioperative hypoxemia and low cardiac output states, sequelae of cardiopulmonary bypass, and deep hypothermic circulatory arrest. Neurological monitoring devices are readily available and the anesthesiologist can now monitor the brain during pediatric cardiac surgery. In this review we discuss near-infrared cerebral oximetry, transcranial Doppler ultrasound, and electroencephalographic monitors for use during congenital heart surgery. After review of the basic principles of each monitoring modality, we discuss their uses during pediatric heart surgery. We present evidence that multimodal neurological monitoring in conjunction with a treatment algorithm may improve neurological outcome for patients undergoing congenital heart surgery and present one such algorithm. IMPLICATIONS: Brain monitoring for pediatric cardiac surgery (near infrared cerebral oximetry, transcranial Doppler ultrasound, and processed electroencephalogram) is now readily available and has the potential to improve neurological outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“Bland-Altman comparison of the 2 devices demonstrated that although the correlation was good when all 60 values were combined, there may be large differences by individual comparison (33).”
BackgroundMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
An introduction to bispectral analysis for the electroencephalogram
Sigl, J. C., & Chamoun, N. G. (1994) · Journal of Clinical Monitoring · doi:10.1007/bf01618421 · Cited by 804 · cited 1×
“Via a proprietary algorithm of Aspect Corporation based on the normal adult EEG, BIS uses Fourier transformation and bispectral analysis of a one-channel processed EEG pattern to compute a single number, the BIS (16).”
MethodBellinger, D. C., Jonas, R. A., Rappaport, L. A., Wypij, D., Wernovsky, G., Kuban, K. C. K., Barnes, P. D., Holmes, G. L., Hickey, P. R., Strand, R. D., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503023320901 · Cited by 802
Newburger, J. W., Jonas, R. A., Wernovsky, G., Wypij, D., Hickey, P. R., Kuban, K., Farrell, D. M., Holmes, G. L., Helmers, S. L., Constantinou, J., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199310073291501 · Cited by 702
An MRI Study of Neurological Injury Before and After Congenital Heart Surgery
Mahle, W. T., Tavani, F., Zimmerman, R. A., Nicolson, S. C., Galli, K. K., Gaynor, J. W., Clancy, R. R., Montenegro, L. M., Spray, T. L., Chiavacci, R. M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000032908.33237.b1 · Cited by 541 · cited 1×
“It would be useful to attempt to correlate abnormal rSO2i with the frequency of changes detected by magnetic resonance imaging after CPB in newborns, specifically periventricular leukomalacia (49).”
BackgroundArterial and Venous Contributions to Near-infrared Cerebral Oximetry
Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00012 · Cited by 451 · cited 2×
“The INVOS 5100 pediatric sensor tends to read significantly higher (by 14% 8%) than the NIRO 300 4 cm interoptode sensor (pediatric equivalent) (31).”
BackgroundMethodHuber, P., & Handa, J. (1967) · Investigative Radiology · doi:10.1097/00004424-196701000-00016 · Cited by 371 · cited 5×
“strategy was used, which can produce relative cerebral vasoconstriction during cooling in smaller arterioles downstream to the MCA and ACA (57).”
MethodInfluentialBenefit of neurophysiologic monitoring for pediatric cardiac surgery
Austin, E. H., Edmonds, H. L., Auden, S. M., Seremet, V., Niznik, G., Sehic, A., Sowell, M. K., Cheppo, C. D., & Corlett, K. M. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70074-6 · Cited by 296 · cited 7×
“A study by Austin et al. ( 4 ) showed that 70% (176 of 250) of pediatric patients experienced a significant change in one or more variables when multimodality neurological monitoring— NIRS, TCD, and four-channel qualitative EEG—was used during cardiac surgery.”
BackgroundMethodInfluentialDreyer, W. J., Michael, L. H., West, M. S., Smith, C. W., Rothlein, R., Rossen, R. D., Anderson, D. C., & Entman, M. L. (1991) · Circulation · doi:10.1161/01.cir.84.1.400 · Cited by 295
Cited by
Andropoulos, D. B., Hunter, J. V., Nelson, D. P., Stayer, S. A., Stark, A. R., McKenzie, E. D., Heinle, J. S., Graves, D. E., & Fraser, C. D. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.08.022 · Cited by 318
Self-citationLemmers, P. M. A., Toet, M. C., & van Bel, F. (2008) · Pediatrics · doi:10.1542/peds.2007-0925 · Cited by 244
Aly, S. A., Zurakowski, D., Glass, P., Skurow-Todd, K., Jonas, R. A., & Donofrio, M. T. (2017) · Congenital Heart Disease · doi:10.1111/chd.12426 · Cited by 77
“pic drugs utilized for stabilization, (2) blood gases in the preoperative, intraoperative and postoperative periods, (3) days in the ICU, (4) length”
Method
Metadata
- Authors
- Andropoulos, D. B., Stayer, S. A., Diaz, L. K., & Ramamoorthy, C.
- Venue
- Anesthesia & Analgesia
- Published
- 2004-11
- Volume
- 99
- Issue
- 5
- Pages
- 1365-1375
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2030844933
- Cited by
- 163
- References
- 51
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neurological Monitoring for Congenital Heart Surgery. https://app.cochat.ai/papers/10.1213/01.ane.0000134808.52676.4d
- The paper
- Andropoulos, D. B., Stayer, S. A., Diaz, L. K., & Ramamoorthy, C. (2004). Neurological Monitoring for Congenital Heart Surgery. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000134808.52676.4d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.