Abstract
SUMMARY Aims To develop a technique to detect microaneurysms automatically in 50° digital red‐free fundus photographs and evaluate its performance as a tool for screening diabetic patients for retinopathy. Methods Candidate microaneurysms are extracted, after the image has been modified to remove variations in background intensity, by algorithms that enhance small round features. Each microaneurysm candidate is then classified according to its intensity and size by the application of a set of rules derived from a training set of 102 images. Results When 3783 individual images were analysed and the results compared with the opinion of a clinical research fellow examining the same images, the program achieved a sensitivity of 81% and a specificity of 93% for the detection of images containing microaneurysms. Nine hundred and twenty‐five sets of 4 images per patient were then analysed and the total number of microaneurysms detected compared with the overall patient retinopathy grade derived by the clinician examining the same images. In this context, intended to mimic a screening situation, the program achieved a sensitivity of 85% and a specificity of 76% for the detection of patients with (any) retinopathy (positive predictive value 0.71, negative predictive value 0.88). Conclusions An automated technique was developed to detect retinopathy in digital red‐free fundus images that can form part of a diabetic retinopathy screening programme. It is believed that it can perform a useful role in this context identifying images worthy of closer inspection or eliminating 50% or more of the screening population who have no retinopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Epidemiology of diabetic retinopathy and macular oedema: A systematic review
Williams, R., Airey, M., Baxter, H., Forrester, J., Kennedy-Martin, T., & Girach, A. (2004) · Eye · doi:10.1038/sj.eye.6701476 · Cited by 472
Self-citationAutomated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Metadata
- Authors
- Hipwell, J. H., Strachan, F., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2000-08
- Volume
- 17
- Issue
- 8
- Pages
- 588-594
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2101384127
- Cited by
- 177
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated detection of microaneurysms in digital red‐free photographs: a diabetic retinopathy screening tool. https://app.cochat.ai/papers/10.1046/j.1464-5491.2000.00338.x
- The paper
- Hipwell, J. H., Strachan, F., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (2000). Automated detection of microaneurysms in digital red‐free photographs: a diabetic retinopathy screening tool. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2000.00338.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.