Reference ranges for fetal venous and atrioventricular blood flow parameters
The DOI matches its Crossref record.
Abstract
This cross‐sectional study establishes reference ranges with gestation for Doppler parameters of fetal venous and atrioventriculur blood flow. Color flow Doppler was used to examine 143 normal singleton pregnancies at 20–40 weeks' gestation. Flow velocity waveforms were recorded from the ductus venosus, right hepatic vein and inferior vena cava. The waveforms are triphasic, reflecting ventricular systole, early diastole and atrial contraction. Peak velocities for these parameters were measured with pulsed Doppler and a new index, the peak velocity index for veins (PVIV), was calculated. Similarly, time‐averaged maximum velocities for the whole cardiac cycle were measured and the pulsatility index for veins (PIV) was calculated. Flow velocity waveforms were also recorded at the level of the atrioventricular valves and the ratios of peak velocities at early diastolic filling (E) and atrial contraction (A) were calculated. Regression analysis was used to define the association of each measured and calculated Doppler parameter with gestational age. Blood flow velocities in the fetal veins and velocities and E/A ratios across the atrioventricular valves increased significantly with gestation, whereas PVIV and PIV decreased. Blood flow velocities were highest in the ductus venosus and lowest in the right hepatic vein, and PVIV and PIV were highest in the hepatic vein and lowest in the ductus venosus. In the ductus venosus, there was always forward flow throughout the heart cycle, whereas in the inferior vena cava and hepatic vein during atrial contraction, flow was away from or towards the heart or there was no flow. Pulsatility of flow velocity waveforms in the venous system is the consequence of changes in pressure difference between the venous system and the heart during the heart cycle. The finding that PVIV and PIV decrease with gestation is consistent with decreasing cardiac afterload and maturation of diastolic ventricular function. Copyright © 1994 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lees, C., Marlow, N., Arabin, B., Bilardo, C. M., Brezinka, C., Derks, J. B., Duvekot, J., Frusca, T., Diemert, A., Ferrazzi, E., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13190 · Cited by 540
“Fetal death No intervention 4 (3) 1 (1) 0 5 (1) Unexpected 3 (2) 4 (2) 0 7 (1) Live birth* 126 (95) 198 (97)* 166 (100) 490 (97) Neonatal death 15 (12) 10 (5) 2 (1) 27 (6) Death with congenital anomaly 0 2 0 2 Overall mortality 22 (17) 15 (7) 2 (1) 39 (8) Survival if liveborn 111 (88) 188 (94) 164 (98) 463 (95) Neonat…”
Self-citationMonitoring of fetuses with intrauterine growth restriction: a longitudinal study
Hecher, K., Bilardo, C. M., Stigter, R. H., Ville, Y., Hackelöer, B. J., Kok, H. J., Senat, M. V., & Visser, G. H. A. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00590.x · Cited by 498
Self-citationLees, C. C., Marlow, N., van Wassenaer-Leemhuis, A., Arabin, B., Bilardo, C. M., Brezinka, C., Calvert, S., Derks, J. B., Diemert, A., Duvekot, J. J., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)62049-3 · Cited by 479
Self-citationISUOG Practice Guidelines: use of Doppler ultrasonography in obstetrics
(2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12371 · Cited by 445
Hecher, K., Campbell, S., Doyle, P., Harrington, K., & Nicolaides, K. (1995) · Circulation · doi:10.1161/01.cir.91.1.129 · Cited by 444
Self-citationFetal growth restriction results in remodeled and less efficient hearts in children
Crispi, F., Bijnens, B., Figueras, F., Bartrons, J., Eixarch, E., Le Noble, F., Ahmed, A., & Gratacós, E. (2010) · Circulation · doi:10.1161/circulationaha.110.937995 · Cited by 435
Baschat, A. A., Gembruch, U., & Harman, C. R. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00591.x · Cited by 435
Cardiac dysfunction and cell damage across clinical stages of severity in growth-restricted fetuses
Crispi, F., Hernandez-Andrade, E., Pelsers, M. M. A. L., Plasencia, W., Benavides-Serralde, J. A., Eixarch, E., Le Noble, F., Ahmed, A., Glatz, J. F. C., Nicolaides, K. H., et al. (2008) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2008.06.056 · Cited by 295
Self-citationBilardo, C. M., Wolf, H., Stigter, R. H., Ville, Y., Baez, E., Visser, G. H. A., & Hecher, K. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.965 · Cited by 278
Self-citationHecher, K., Snijders, R., Campbell, S., & Nicolaides, K. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90161-2 · Cited by 270
Self-citationISUOG Practice Guidelines (updated): use of Doppler velocimetry in obstetrics
Bhide, A., Acharya, G., Baschat, A., Bilardo, C. M., Brezinka, C., Cafici, D., Ebbing, C., Hernandez‐Andrade, E., Kalache, K., Kingdom, J., et al. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23698 · Cited by 265
A cardiovascular profile score in the surveillance of fetal hydrops
Hofstaetter, C., Hofstaetter, C., Hansmann, M., Eik-Nes, S. H., Huhta, J. C., & Luther, S. L. (2006) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050600682446 · Cited by 173
The fetal lung 2: pulmonary hypoplasia
Laudy, J. A. M., & Wladimiroff, J. W. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00252.x · Cited by 158
Yagel, S., Kivilevitch, Z., Cohen, S. M., Valsky, D. V., Messing, B., Shen, O., & Achiron, R. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7622 · Cited by 129
Cruz-Lemini, M., Crispi, F., Valenzuela-Alcaraz, B., Figueras, F., Sitges, M., Bijnens, B., & Gratacós, E. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15767 · Cited by 116
Stampalija, T., Arabin, B., Wolf, H., Bilardo, C. M., Lees, C., Brezinka, C., Derks, J. B., Diemert, A., Duvekot, J. J., Ferrazzi, E., et al. (2017) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.01.001 · Cited by 95
Self-citationMeler, E., Mazarico, E., Eixarch, E., Gonzalez, A., Peguero, A., Martinez, J., Boada, D., Vellvé, K., Gomez‐Roig, M. D., Gratacós, E., et al. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23537 · Cited by 36
Role of ultrasound in the management of diabetes in pregnancy
Ahmed, B., Abushama, M., Khraisheh, M., & Dudenhausen, J. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2014.971745 · Cited by 24
“We then document absent or reversed wave velocity [79,80].”
Background
Metadata
- Authors
- Hecher, K., Campbell, S., Snijders, R., & Nicolaides, K.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 4
- Issue
- 5
- Pages
- 381-390
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1979490938
- Cited by
- 317
- References
- 0
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.