The DOI matches its Crossref record.
Increased nuchal translucency at 10—14 weeks of gestation as a marker for major cardiac defects
Open accessAbstract
Screening for fetal cardiac defects is traditionally based on the ultrasonographic examination of the four‐chamber view of the fetal heart at mid‐gestation, which has been shown to identify 26% of major cardiac defects. Pathological studies in fetuses with increased nuchal translucency at 10–l4 weeks of gestation, a sonographic marker for chromosomal abnormalities, have shown an association between increased nuchal translucency and congenital abnormalities of the heart. This study reports the prevalence of cardiac defects in 1427 chromosomally normal fetuses with increased nuchal translucency thickness, and examines the potential value of this sonographic marker in screening for major cardiac defects. The diagnosis of cardiac defects was made either by postmortem examination in terminations of pregnancy and intrauterine or neonatal deaths or by clinical examination and appropriate investigations in live births. The prevalence of major cardiac defects was 17 per 1000 (24 of 1427 fetuses) and increased with translucency thickness from 5.4 per 1000 for translucency of 2.5–3.4 mm to 233 per 1000 for translucency of ≥ 5.5 mm. These findings suggest that measurement of nuchal translucency thickness at 10–l4 weeks may prove to be a useful method of screening for abnormalities of the heart and great arteries in addition to its role in screening for chromosomal defects. Copyright © 1997 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
Self-citationDugoff, L., Hobbins, J. C., Malone, F. D., Porter, T. F., Luthy, D., Comstock, C. H., Hankins, G., Berkowitz, R. L., Merkatz, I., Craigo, S. D., et al. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.052 · Cited by 624
Metadata
- Authors
- Hyett, J. A., Perdu, M., Sharland, G. K., Snijders, R. S. M., & Nicolaides, K. H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 10
- Issue
- 4
- Pages
- 242-246
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2082984582
- Cited by
- 235
- References
- 0
- FWCI
- 15.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased nuchal translucency at 10—14 weeks of gestation as a marker for major cardiac defects. https://app.cochat.ai/papers/10.1046/j.1469-0705.1997.10040242.x
- The paper
- Hyett, J. A., Perdu, M., Sharland, G. K., Snijders, R. S. M., & Nicolaides, K. H. (1997). Increased nuchal translucency at 10—14 weeks of gestation as a marker for major cardiac defects. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.1997.10040242.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.