Increased nuchal translucency at 10—14 weeks of gestation as a marker for major cardiac defects
Open accessThe DOI matches its Crossref record.
Abstract
Screening for fetal cardiac defects is traditionally based on the ultrasonographic examination of the four‐chamber view of the fetal heart at mid‐gestation, which has been shown to identify 26% of major cardiac defects. Pathological studies in fetuses with increased nuchal translucency at 10–l4 weeks of gestation, a sonographic marker for chromosomal abnormalities, have shown an association between increased nuchal translucency and congenital abnormalities of the heart. This study reports the prevalence of cardiac defects in 1427 chromosomally normal fetuses with increased nuchal translucency thickness, and examines the potential value of this sonographic marker in screening for major cardiac defects. The diagnosis of cardiac defects was made either by postmortem examination in terminations of pregnancy and intrauterine or neonatal deaths or by clinical examination and appropriate investigations in live births. The prevalence of major cardiac defects was 17 per 1000 (24 of 1427 fetuses) and increased with translucency thickness from 5.4 per 1000 for translucency of 2.5–3.4 mm to 233 per 1000 for translucency of ≥ 5.5 mm. These findings suggest that measurement of nuchal translucency thickness at 10–l4 weeks may prove to be a useful method of screening for abnormalities of the heart and great arteries in addition to its role in screening for chromosomal defects. Copyright © 1997 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“The indication that has yielded the greatest number of pregnancies with a fetal cardiac diagnosis in a series of late first– and early second–trimester diagnoses is the finding of an increased NT noted on first-trimester screening ultrasound.(184,185) In the absence of aneuploidy, a variety of fetal heart defects have…”
BackgroundISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
Self-citationDugoff, L., Hobbins, J. C., Malone, F. D., Porter, T. F., Luthy, D., Comstock, C. H., Hankins, G., Berkowitz, R. L., Merkatz, I., Craigo, S. D., et al. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.052 · Cited by 624
Hyett, J., Perdu, M., Sharland, G., Snijders, R., & Nicolaides, K. H. (1999) · BMJ · doi:10.1136/bmj.318.7176.81 · Cited by 611
Self-citationIncreased nuchal translucency with normal karyotype
Souka, A. P., von Kaisenberg, C. S., Hyett, J. A., Sonek, J. D., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.093 · Cited by 517
Self-citationSouka, A. P., Snijders, R. J. M., Novakov, A., Soares, W., & Nicolaides, K. H. (1998) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1998.11060391.x · Cited by 479
Self-citationSyngelaki, A., Hammami, A., Bower, S., Zidere, V., Akolekar, R., & Nicolaides, K. H. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20844 · Cited by 350
Self-citationTegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2710 · Cited by 308
Yagel, S., Cohen, S. M., & Achiron, R. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00414.x · Cited by 299
(2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2677 · Cited by 256
ISUOG Practice Guidelines (updated): fetal cardiac screening
Carvalho, J. S., Axt‐Fliedner, R., Chaoui, R., Copel, J. A., Cuneo, B. F., Goff, D., Gordin Kopylov, L., Hecher, K., Lee, W., Moon‐Grady, A. J., et al. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26224 · Cited by 246
“For example, nuchal translucency thickness ≥ 3.5 mm at 11–14 weeks’ gestation is an indication for a detailed cardiac evaluation 108–110 even if the measurement subsequently falls within the normal range.”
BackgroundInfluentialRossi, A. C., & Prefumo, F. (2013) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000015 · Cited by 224
Fanaroff, A. A. (2008) · Yearbook of Neonatal and Perinatal Medicine · doi:10.1016/s8756-5005(08)79214-x · Cited by 207
Fetal cells in the maternal circulation: feasibility for prenatal diagnosis
Bianchi, D. W. (1999) · British Journal of Haematology · doi:10.1046/j.1365-2141.1999.01383.x · Cited by 188
“An increased NT measurement over that expected for gestational age is associated with an increased risk of fetal chromosome and cardiac abnormalities (Nicolaides et al, 1992; Hyett et al, 1997).”
BackgroundIncreased fetal nuchal translucency at 11–14 weeks
Nicolaides, K. H., Heath, V., & Cicero, S. (2002) · Prenatal Diagnosis · doi:10.1002/pd.308 · Cited by 182
“Studies involving pathological examination in both chromosomally abnormal and normal fetuses with increased NT at 11–14 weeks have demonstrated a high prevalence of abnormalities of the heart and great arteries (Hyett et al., 1997a,b).”
BackgroundSelf-citationCarlson, L. M., & Vora, N. L. (2017) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2017.02.004 · Cited by 179
3D and 4D ultrasound in fetal cardiac scanning: a new look at the fetal heart
Yagel, S., Cohen, S. M., Shapiro, I., & Valsky, D. V. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.3912 · Cited by 174
Ghi, T., Huggon, I. C., Zosmer, N., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00584.x · Cited by 167
Self-citationHutchinson, D., McBrien, A., Howley, L., Yamamoto, Y., Sekar, P., Motan, T., Jain, V., Savard, W., & Hornberger, L. K. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.03.017 · Cited by 77
Metadata
- Authors
- Hyett, J. A., Perdu, M., Sharland, G. K., Snijders, R. S. M., & Nicolaides, K. H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 10
- Issue
- 4
- Pages
- 242-246
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2082984582
- Cited by
- 235
- References
- 0
- FWCI
- 15.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.