CoChat

Anomalies of the fetal aortic arch: a novel sonographic approach to in‐utero diagnosis

Achiron, R., Rotstein, Z., Heggesh, J., Bronshtein, M., Zimand, S., Lipitz, S., Yagel, S. · 2002 · Ultrasound in Obstetrics & Gynecology
Cited by 159

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Objective: To describe a novel, sonographic approach for in‐utero evaluation of normal and abnormal aortic arch. Methods: Aortic arch was evaluated by imaging of the axial view of the upper fetal mediastinum. The normal left aortic arch was defined by the V‐shaped appearance of the junction between the ductus arteriosus and aortic arch, with the trachea situated posteriorly. Right and double aortic arches were diagnosed when the great vessels appeared U‐shaped, with intermediate location of the trachea. Results: Between 1997 and 1999, 18 347 women were scanned in three prenatal centers, and pathological findings were prospectively recorded. In a retrospective analysis of the records, we identified 19 fetuses (0.1%) with atypical, U‐shaped appearance, and no other structural abnormalities present. With the exception of one fetus with a ventricular septal defect, no congenital cardiac defects were present. Right aortic arch was found in 18 cases, while color Doppler made it possible to diagnose one case with double aortic arch, and one fetus was demonstrated as having Kommerell's diverticulum. In all 18 cases, a left descending aorta and left ductus arteriosus were present, the latter coursing to the left of the trachea, forming a loose partial vascular ring. All were asymptomatic at birth and early infancy. The fetus with double aortic arch that had a true vascular ring underwent early infantile correction. Conclusions: It is possible to diagnose right and double fetal aortic arch using prenatal ultrasound. The use of color Doppler facilitated in‐utero evaluation of possible complications, such as true vascular ring. Copyright © 2002 International Society of Ultrasound in Obstetrics and Gynecology

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-0705.2002.00850.x

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 159

Metadata

Authors
Achiron, R., Rotstein, Z., Heggesh, J., Bronshtein, M., Zimand, S., Lipitz, S., & Yagel, S.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2002-12
Volume
20
Issue
6
Pages
553-557
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2057244082
Cited by
159
References
9
FWCI
2.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anomalies of the fetal aortic arch: a novel sonographic approach to in‐utero diagnosis. https://app.cochat.ai/papers/10.1046/j.1469-0705.2002.00850.x
The paper
Achiron, R., Rotstein, Z., Heggesh, J., Bronshtein, M., Zimand, S., Lipitz, S., & Yagel, S. (2002). Anomalies of the fetal aortic arch: a novel sonographic approach to in‐utero diagnosis. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.2002.00850.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.