3D In-Vivo Optical Skin Imaging for Topographical Quantitative Assessment of Non-Ablative Laser Technology
The DOI matches its Crossref record.
Abstract
BACKGROUND: A new method for treating facial rhytides and acne scars with nonablative laser and light source techniques has recently been introduced. Given the inherent limitations of photographic and clinical evaluation to assess subtle changes in rhytides and surface topography, a new noninvasive objective assessment is required to accurately assess the outcomes of these procedures. OBJECTIVE: The purpose of this study was to measure and objectively quantify facial skin using a novel, noninvasive, In-vivo method for assessing three-dimensional topography. This device was used to quantify the efficacy of five treatment sessions with the 1064 nm QS Nd:YAG laser for rhytides and acne scarring, for up to six months following laser treatment. METHODS: Two subjects undergoing facial rejuvenation procedures were analyzed before and after therapy using a 30-mm, three-dimensional microtopography imaging system (PRIMOS, GFM, Teltow, Germany). The imaging system projects light on to a specific surface of the skin using a Digital Micromirror Device (DMD Texas Instruments, Irving, TX) and records the image with a CCD camera. Skin Surface microtopography is reconstructed using temporal phase shift algorithms to generate three-dimensional images. Measurements were taken at baseline, at various times during the treatment protocol, and then at three and six-month follow-up visits. Silicone skin replicas (FLEXICO, Herts, England) were also made before and after the laser treatment protocol for comparison to In-vivo acquisition. RESULTS: Skin roughness decreased by 11% from baseline after three treatment sessions in the wrinkles subject, while a 26% improvement of skin roughness was recorded by 3D In-vivo assessment six months following the fifth treatment session. The subject with acne scarring demonstrated a 33% decrease in roughness analysis after three treatment sessions by 3D In-vivo assessment. A 61% improvement in surface topography was recorded 3-months following the fifth treatment session, which was maintained at the 6-month follow-up. CONCLUSION: Three-dimensional In-vivo optical skin imaging provided a rapid and quantitative assessment of surface topography and facial fine lines following multiple treatment sessions with a 1064-nm QS Nd:YAG laser, correlating with clinical and subjective responses. This imaging technique provided objective verification and technical understanding of nonablative laser technology. Wrinkle depth and skin roughness decreased at the three and six-month follow-up evaluations by 3D In-vivo assessment, indicating ongoing dermal collagen remodeling after the laser treatment protocol. Future applications may include comparison of nonablative laser technology, optimization of treatment regimens, and objective evaluation of other aesthetic procedures performed by dermatologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acne scarring: A review and current treatment modalities
Rivera, A. E. (2008) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2008.05.029 · Cited by 259
Tanzi, E. L., & Alster, T. S. (2004) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2004.30078.x · Cited by 241
“Although optical profilometry using silicone rubber skin replicas has been used to measure surface textural changes successfully in the past, it can be operator dependent and is subject to a variety of artifacts.(42,43) Although the PRIMOS system can also be difficult to master, once the technique is learned, its in v…”
MethodWATTANAKRAI, P., MORNCHAN, R., & EIMPUNTH, S. (2010) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2009.01383.x · Cited by 227
Biological Background of Dermal Substitutes
van der Veen, V. C., van der Wal, M. B. A., van Leeuwen, M. C. E., Ulrich, M. M. W., & Middelkoop, E. (2010) · Burns · doi:10.1016/j.burns.2009.07.012 · Cited by 222
Bolke, L., Schlippe, G., Gerß, J., & Voss, W. (2019) · Nutrients · doi:10.3390/nu11102494 · Cited by 198
“The technology reproducibly determines skin roughness [19].”
Update on non‐ablative light therapy for rejuvenation: A review
Sadick, N. S. (2003) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10127 · Cited by 173
“Three-dimensional in vivo optical skin imaging for topographical quantitative assessment of non-ablative laser technologies has also been helpful in this setting [6].”
BackgroundLademann, J., Meinke, M. C., Sterry, W., & Darvin, M. E. (2011) · Experimental Dermatology · doi:10.1111/j.1600-0625.2010.01189.x · Cited by 121
Boo, Y. C. (2019) · Antioxidants · doi:10.3390/antiox8090332 · Cited by 119
Metadata
- Authors
- Friedman, P. M., Skover, G. R., Payonk, G., Kauvar, A. N. B., & Geronemus, R. G.
- Venue
- Dermatologic Surgery
- Published
- 2002-03
- Volume
- 28
- Issue
- 3
- Pages
- 199-204
- ISSN
- 1076-0512 (ISSN-L)
- 1524-4725
- OpenAlex
- W1997038019
- Cited by
- 150
- References
- 0
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).