CoChat

Second‐Generation Microstimulator

Arcos, Isabel, Davis, R., Fey, K., Mishler, D., Sanderson, D., Tanacs, C., Vogel, M.J., Wolf, R., Zilberman, Y., Schulman, J. · 2002 · Artificial Organs
Cited by 39

The DOI matches its Crossref record.

Abstract

The first‐generation injectable microstimulator was glass encased with an external tantalum capacitor electrode. This second‐generation device uses a hermetically sealed ceramic case with platinum electrodes. Zener diodes protect the electronics from defibrillation shocks and from electrostatic discharge. The capacitor is sealed inside the case so that it cannot be inadvertently damaged by surgical instruments. This microstimulator, referred to as BION, is the main component of a 255‐channel wireless stimulating system. BION devices have been implanted in rats for periods of up to 5 months. Results show benign tissue reactions resulting in identical encapsulation around BION and controls. Stimulation threshold levels did not change significantly over time and ranged between 0.81 to 1.35 mA for all the animals at a 60 μs pulse width. All of the tests performed to date indicate that the BION is safe and effective for long‐term human implant. We have elected to develop BION applications by seeking collaboration with the research community through our BION Technology Partnership.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1525-1594.2002.06938.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 7

  1. Loeb GE Richmond FJR Olney S Cameron T. Bionic neurons for functional and theurapeutic electrical stimulation. 20th Annual IEEE‐EMBS Oct.29–Nov. 1 1998 Hong Kong.
  2. 10.1109/10.623047 · DOI · Paper page
  3. 10.1109/10.704872 · DOI · Paper page
  4. 10.1109/10.704871 · DOI · Paper page
  5. 10.1007/BF02446097 · DOI
  6. 10.1109/10.141197 · DOI · Paper page
  7. Guajardo A Sutherland H Jarvis JC Salmons S. Conditioning muscles for fatigue resistance: the effect of on/off pattern. Proceedings of the 5th Annual IFESS Conference Sinkjaer Denmark 2000;119.

Cited by

See all 39

Metadata

Authors
Arcos, I., Davis, R., Fey, K., Mishler, D., Sanderson, D., Tanacs, C., Vogel, M. J., Wolf, R., Zilberman, Y., & Schulman, J.
Venue
Artificial Organs
Publisher
Wiley
Published
2002-03
Volume
26
Issue
3
Pages
228-231
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2062702752
Cited by
39
References
0
FWCI
0.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Second‐Generation Microstimulator. https://app.cochat.ai/papers/10.1046/j.1525-1594.2002.06938.x
The paper
Arcos, I., Davis, R., Fey, K., Mishler, D., Sanderson, D., Tanacs, C., Vogel, M. J., Wolf, R., Zilberman, Y., & Schulman, J. (2002). Second‐Generation Microstimulator. Artificial Organs. https://doi.org/10.1046/j.1525-1594.2002.06938.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.