The DOI matches its Crossref record; 181 of the 181 references it cites were found in a registry or an index.
Wireless Power Transfer Strategies for Implantable Bioelectronics
Abstract
Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antenna Theory: Analysis and Design
Balanis, C. A. (1982) · Cited by 10,178
Pozar, D. M. (1990) · Cited by 8,065
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Physical limitations of omnidirectional antennas
(1948) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 2,235
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
Sokal, N. O., & Sokal, A. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050582 · Cited by 2,033
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Sample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
The History of Power Transmission by Radio Waves
Brown, W. C. (1984) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1984.1132833 · Cited by 1,638
Cited by
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“In [35], different WPT techniques and their design issues are reviewed.”
BackgroundInfluentialLarge-Area Soft e-Skin: The Challenges Beyond Sensor Designs
Dahiya, R., Yogeswaran, N., Liu, F., Manjakkal, L., Burdet, E., Hayward, V., & Jörntell, H. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2941366 · Cited by 309
Metadata
- Authors
- Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2017
- Volume
- 10
- Pages
- 136-161
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2596697137
- Cited by
- 540
- References
- 181
- FWCI
- 18.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless Power Transfer Strategies for Implantable Bioelectronics. https://app.cochat.ai/papers/10.1109/rbme.2017.2683520
- The paper
- Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017). Wireless Power Transfer Strategies for Implantable Bioelectronics. IEEE Reviews in Biomedical Engineering. https://doi.org/10.1109/rbme.2017.2683520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.