The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multimodal Hyperspectral Imaging for the Noninvasive Diagnosis of Cervical Neoplasia
Abstract
OBJECTIVE: To determine the ability of Multimodal Hyperspectral Imaging (MHI) to noninvasively detect, localize and diagnose cervical neoplasia. MATERIALS AND METHODS: The cervical epithelium was interrogated by MHI using tissue fluorescence and reflectance measurements after the probe was placed on the ectocervix. A Papanicolaou smear was taken, and a colposcopic examination was performed and cervical histologic specimens were collected, when indicated. MHI and Pap smear sensitivity and specificity data were compared with colposcopic and histologic results. RESULTS: Nineteen patients had CIN2 or higher, 30 had CIN1, 34 had benign cellular changes or metaplasia, and 28 were normal by both Pap smear and colposcopic examination. At equal specificity (70%) for both tests, the sensitivity of MHI was 97%, compared to 72% for the Pap smear. CONCLUSION: MHI detected cervical cancer precursors at a rate greater than that obtained by a simultaneously collected Pap smear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical data analysis in the computer age
Efron, B., & Tibshirani, R. (1991) · Science · doi:10.1126/science.253.5018.390 · Cited by 1,192
Cited by
Medical hyperspectral imaging: a review
Lu, G., & Fei, B. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.010901 · Cited by 2,291
Hyperspectral imaging – an emerging process analytical tool for food quality and safety control
GOWEN, A., ODONNELL, C., CULLEN, P., DOWNEY, G., & FRIAS, J. (2007) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2007.06.001 · Cited by 1,412
Recycling of plastic solid waste: A state of art review and future applications
Singh, N., Hui, D., Singh, R., Ahuja, I. P. S., Feo, L., & Fraternali, F. (2017) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2016.09.013 · Cited by 1,211
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Drezek, R., Guillaud, M., Collier, T., Boiko, I., Malpica, A., Macaulay, C., Follen, M., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528950 · Cited by 255
Metadata
- Authors
- Ferris, D. G., Lawhead, R. A., Dickman, E. D., Holtzapple, N., Miller, J. A., Grogan, S., Bambot, S., Agrawal, A., & Faupel, M. L.
- Venue
- Journal of Lower Genital Tract Disease
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 5
- Issue
- 2
- Pages
- 65-72
- ISSN
- 1089-2591 (ISSN-L)
- 1526-0976
- OpenAlex
- W2161271315
- Cited by
- 158
- References
- 1
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multimodal Hyperspectral Imaging for the Noninvasive Diagnosis of Cervical Neoplasia. https://app.cochat.ai/papers/10.1046/j.1526-0976.2001.005002065.x
- The paper
- Ferris, D. G., Lawhead, R. A., Dickman, E. D., Holtzapple, N., Miller, J. A., Grogan, S., Bambot, S., Agrawal, A., & Faupel, M. L. (2001). Multimodal Hyperspectral Imaging for the Noninvasive Diagnosis of Cervical Neoplasia. Journal of Lower Genital Tract Disease. https://doi.org/10.1046/j.1526-0976.2001.005002065.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.