Multimodal Hyperspectral Imaging for the Noninvasive Diagnosis of Cervical Neoplasia
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the ability of Multimodal Hyperspectral Imaging (MHI) to noninvasively detect, localize and diagnose cervical neoplasia. MATERIALS AND METHODS: The cervical epithelium was interrogated by MHI using tissue fluorescence and reflectance measurements after the probe was placed on the ectocervix. A Papanicolaou smear was taken, and a colposcopic examination was performed and cervical histologic specimens were collected, when indicated. MHI and Pap smear sensitivity and specificity data were compared with colposcopic and histologic results. RESULTS: Nineteen patients had CIN2 or higher, 30 had CIN1, 34 had benign cellular changes or metaplasia, and 28 were normal by both Pap smear and colposcopic examination. At equal specificity (70%) for both tests, the sensitivity of MHI was 97%, compared to 72% for the Pap smear. CONCLUSION: MHI detected cervical cancer precursors at a rate greater than that obtained by a simultaneously collected Pap smear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical data analysis in the computer age
Efron, B., & Tibshirani, R. (1991) · Science · doi:10.1126/science.253.5018.390 · Cited by 1,192 · cited 1×
“Confidence intervals and resampling cross validation techniques were used to evaluate the robustness of the results [22].”
MethodBiostatistics: A Methodology for the Health Sciences.
D'Agostino, R. B., Fisher, L. D., & van Belle, G. (1995) · Journal of the American Statistical Association · doi:10.2307/2291095 · Cited by 957
Meta-analysis of Pap Test Accuracy
Fahey, M. T., Irwig, L., & Macaskill, P. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117485 · Cited by 684 · cited 1×
“An imperfect screening test, a lengthy Papanicolaou (Pap) smear collection to notification interval, and a substantial patient noncompliance rate with recommended practices may all adversely impact the screening process [1–8].”
BackgroundThe Papanicolaou Test for Cervical Cancer Detection: A Triumph and a Tragedy
Koss, L. G. (1989) · JAMA · doi:10.1001/jama.1989.03420050087046 · Cited by 645
Ramanujam, N., Mitchell, M. F., Mahadevan, A., Warren, S., Thomsen, S., Silva, E., & Richards-Kortum, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10193 · Cited by 253 · cited 3×
“Tissue fluorescence and reflected light measurements are analyzed using computer-based algorithms to determine whether the tissue is normal or abnormal; however, these systems have not been studied extensively [14, 17, 18].”
BackgroundMethodRamanujam, N., Mitchell, M. F., Mahadevan‐Jansen, A., Thomson, S. L., Staerkel, G., Malpica, A., Wright, T., Atkinson, N., & Richards‐Kortum, R. (1996) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1996.tb03130.x · Cited by 227 · cited 2×
“, tryptophan, flavins, collagen), to emit light when excited by specific wavelengths of light, with the peak intensity in a different, but corresponding frequency band [12, 13, 14, 15, 16].”
BackgroundFluorescence Spectroscopy: A Diagnostic Tool for Cervical Intraepithelial Neoplasia (CIN)
Ramanujam, N., Mitchell, M. F., Mahadevan, A., Thomsen, S., da Silva, E. L., & Richards-Kortum, R. R. (1994) · Gynecologic Oncology · doi:10.1006/gyno.1994.1007 · Cited by 164 · cited 1×
“, tryptophan, flavins, collagen), to emit light when excited by specific wavelengths of light, with the peak intensity in a different, but corresponding frequency band [12, 13, 14, 15, 16].”
BackgroundFLUORESCENCE SPECTROSCOPY FOR DIAGNOSIS OF SQUAMOUS INTRAEPITHELIAL LESIONS OF THE CERVIX
Mitchell, M. F., Cantor, S. B., Ramanujam, N., Tortolero‐Luna, G., & Richards-Kortum, R. R. (1999) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00385-8 · Cited by 123 · cited 1×
“A noninvasive cervical neoplasia detection system based on fluorescence spectroscopy has been shown to perform better than colposcopy, cervicography, cervical cytology, and HPV testing, which are all current methods used to screen, triage, and diagnose cervical neoplasia [10].”
MethodStewart, D. E., Buchegger, P., Lickrish, G. M., & Sierra, S. (1994) · Obstetrics and Gynecology · doi:10.1097/00006250-199404000-00016 · Cited by 70 · cited 1×
“An imperfect screening test, a lengthy Papanicolaou (Pap) smear collection to notification interval, and a substantial patient noncompliance rate with recommended practices may all adversely impact the screening process [1–8].”
BackgroundRichards-Kortum, R. R., Mitchell, M. F., Ramanujam, N., Mahadevan, A., & Thomsen, S. (1994) · PubMed · Cited by 57
Compliance With Therapy for Cervical Dysplasia Among Women of Low Socioeconomic Status
Laedtke, T. W., & Dignan, M. (1992) · Southern Medical Journal · doi:10.1097/00007611-199201000-00003 · Cited by 48
Cited by
Medical hyperspectral imaging: a review
Lu, G., & Fei, B. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.010901 · Cited by 2,291
Hyperspectral imaging – an emerging process analytical tool for food quality and safety control
GOWEN, A., ODONNELL, C., CULLEN, P., DOWNEY, G., & FRIAS, J. (2007) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2007.06.001 · Cited by 1,412
Recycling of plastic solid waste: A state of art review and future applications
Singh, N., Hui, D., Singh, R., Ahuja, I. P. S., Feo, L., & Fraternali, F. (2017) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2016.09.013 · Cited by 1,211
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Drezek, R., Guillaud, M., Collier, T., Boiko, I., Malpica, A., Macaulay, C., Follen, M., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528950 · Cited by 255
Metadata
- Authors
- Ferris, D. G., Lawhead, R. A., Dickman, E. D., Holtzapple, N., Miller, J. A., Grogan, S., Bambot, S., Agrawal, A., & Faupel, M. L.
- Venue
- Journal of Lower Genital Tract Disease
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 5
- Issue
- 2
- Pages
- 65-72
- ISSN
- 1089-2591 (ISSN-L)
- 1526-0976
- OpenAlex
- W2161271315
- Cited by
- 158
- References
- 11
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.