Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cervical Precancer Detection Using a Multivariate Statistical Algorithm Based on Laser‐Induced Fluorescence Spectra at Multiple Excitation Wavelengths

Ramanujam, Nirmala, Mitchell, Michele Follen, Mahadevan‐Jansen, Anita, Thomson, Sharon L., Staerkel, Gregg, Malpica, Anais, Wright, Thomas, Atkinson, Neely, Richards‐Kortum, Rebecca · 1996 · Photochemistry and Photobiology

Abstract

A portable fluorimeter was developed and utilized to acquire fluorescence spectra from 381 cervical sites in 95 patients at 337, 380 and 460 nm excitation immediately prior to colposcopy. A multivariate statistical algorithm was used to extract clinically useful information from tissue spectra acquired in vivo. Two full‐parameter algorithms were developed using tissue fluorescence emission spectra at all three excitation wavelengths (161 excitation‐emission wavelength pairs) for cervical precancer (squamous intraepithelial lesion [SIL]) detection: a screening algorithm that discriminates between SIL and non‐SIL with a sensitivity of 82 ± 1.4% and specificity of 68 ± 0.0%, and a diagnostic algorithm that differentiates high‐grade SIL from non‐high‐grade SIL with a sensitivity and specificity of 79 ± 2% and 78 ± 6%, respectively. Multivariate statistical analysis was also employed to reduce the number of fluorescence excitation‐emission wavelength pairs needed to redevelop algorithms that demonstrate a minimum decrease in classification accuracy. Two reduced‐parameter algorithms that employ fluorescence intensities at only 15 excitation‐emission wavelength pairs were developed: the screening algorithm differentiates SIL from non‐SIL with a sensitivity of 84 ± 1.5% and specificity of 65 ± 2% and the diagnostic algorithm discriminates high‐grade SIL from non‐high‐grade SIL with a sensitivity and specificity of 78 ± 0.7% and 74 ± 2%, respectively. Both the full‐parameter and reduced‐parameter screening algorithms discriminate between SIL and non‐SIL with a similar specificity (±5%) and a substantially improved sensitivity relative to Pap smear screening. A comparison of the full‐parameter and reduced‐parameter diagnostic algorithms to colposcopy in expert hands indicates that all three have a very similar sensitivity and specificity for differentiating high‐grade SIL from non‐high‐grade SIL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1751-1097.1996.tb03130.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
Ramanujam, N., Mitchell, M. F., Mahadevan‐Jansen, A., Thomson, S. L., Staerkel, G., Malpica, A., Wright, T., Atkinson, N., & Richards‐Kortum, R.
Venue
Photochemistry and Photobiology
Publisher
Wiley
Published
1996-10
Volume
64
Issue
4
Pages
720-735
ISSN
  • 0031-8655 (ISSN-L)
  • 1751-1097
OpenAlex
W2160721212
Cited by
227
References
1
FWCI
8.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cervical Precancer Detection Using a Multivariate Statistical Algorithm Based on Laser‐Induced Fluorescence Spectra at Multiple Excitation Wavelengths. https://app.cochat.ai/papers/10.1111/j.1751-1097.1996.tb03130.x
The paper
Ramanujam, N., Mitchell, M. F., Mahadevan‐Jansen, A., Thomson, S. L., Staerkel, G., Malpica, A., Wright, T., Atkinson, N., & Richards‐Kortum, R. (1996). Cervical Precancer Detection Using a Multivariate Statistical Algorithm Based on Laser‐Induced Fluorescence Spectra at Multiple Excitation Wavelengths. Photochemistry and Photobiology. https://doi.org/10.1111/j.1751-1097.1996.tb03130.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.