Epileptic Spikes: Magnetoencephalography versus Simultaneous Electrocorticography
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To test the sensitivity of extracranial magnetoencephalography (MEG) for epileptic spikes in different cerebral sites. Methods: We simultaneously recorded MEG and electrocorticography (ECoG) by using subdural electrodes with 1‐cm interelectrode distances for one patient with lateral frontal epilepsy and one patient with basal temporal epilepsy. We analyzed MEG spikes associated with ECoG spikes and compared the maximal amplitude and number of electrodes involved. We estimated and evaluated the locations and moments of the equivalent current dipoles (ECDs) of MEG spikes. Results: In patient 1, MEG detected 100 (53%) of 188 ECoG lateral frontal spikes, including 31 (46%) of 67 spikes that activated three subdural electrodes. MEG spike amplitudes correlated with ECoG spike amplitudes and the number of electrodes activated (p < 0.01). ECDs were perpendicular to the superior frontal sulcus. In patient 2, MEG detected 31 (26%) of 121 ECoG basal temporal spikes, but none that activated only three subdural electrodes. ECDs were localized in the entorhinal and parahippocampal gyri, oriented perpendicular to those basal temporal cortical surfaces. The ECD strength was 136.6 ± 71.5 nAm in the frontal region, but 274.5 ± 150.6 nAm in the temporal region (p < 0.01). Conclusions: When lateral frontal ECoG spikes extend >3 cm 2 across the fissure, MEG can detect >50%, correlating with spatial activation and voltage. In the basal temporal region, MEG requires higher‐amplitude discharges over a more extensive area. MEG shows a significantly higher sensitivity to lateral convexity epileptic discharges than to discharges in isolated deep basal temporal regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 1×
“Magnetoencephalography (MEG) measures the extracranial magnetic fields generated by intraneuronal electric currents with superconducting quantum interference devices (1).”
BackgroundEEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Cited by
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Barkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“…to 4 cm2 of synchronized epileptic activity involving the lateral neocortex was necessary to produce a detectable MEG signal at the scalp (Baumgartner et al., 1992; Mikuni et al., 1997; Oishi et al., 2002), which is smaller than the classical 6 cm2 proposed for the scalp-EEG (Cooper et al., 1965).”
BackgroundKnowlton, R. C., Elgavish, R., Howell, J., Blount, J., Burneo, J. G., Faught, E., Kankirawatana, P., Riley, K., Morawetz, R., Worthington, J., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20857 · Cited by 169
Scalp EEG is not a Blur: It Can See High Frequency Oscillations Although Their Generators are Small
Zelmann, R., Lina, J. M., Schulze-Bonhage, A., Gotman, J., & Jacobs, J. (2014) · Brain Topography · doi:10.1007/s10548-013-0321-y · Cited by 163
Utilization of magnetoencephalography results to obtain favourable outcomes in epilepsy surgery
Fischer, M. J. M. (2004) · Brain · doi:10.1093/brain/awh333 · Cited by 159
“MEG results in presurgical evaluation have been evaluated by several diagnostic methods, especially electrocorticogram (Mamelak et al., 2002; Oishi et al., 2002).”
Method
Metadata
- Authors
- Oishi, M., Otsubo, H., Kameyama, S., Morota, N., Masuda, H., Kitayama, M., & Tanaka, R.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 43
- Issue
- 11
- Pages
- 1390-1395
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1977181559
- Cited by
- 158
- References
- 2
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.