The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
MEG and EEG in Epilepsy
Abstract
Both EEG and magnetoencephalogram (MEG), with a time resolution of 1 ms or less, provide unique neurophysiologic data not obtainable by other neuroimaging techniques. MEG has now emerged as a mature clinical technology. While both EEG and MEG can be performed with more than 100 channels, MEG recordings with 100 to 300 channels are more easily done because of the time needed to apply a large number of EEG electrodes. EEG has the advantage of the long-term video EEG recordings, which facilitates extensive temporal sampling across all periods of the sleep/wake cycle. MEG and EEG seem to complement each other for the detection of interictal epileptiform discharges, because some spikes can be recorded only on MEG but not on EEG and vice versa. Most studies indicate that MEG seems to be more sensitive for neocortical spike sources. Both EEG and MEG source localizations show excellent agreement with invasive electrical recordings, clarify the spatial relationship between the irritative zone and structural lesions, and finally, attribute epileptic activity to lobar subcompartments in temporal lobe and to a lesser extent in extratemporal epilepsies. In temporal lobe epilepsy, EEG and MEG can differentiate between patients with mesial, lateral, and diffuse seizure onsets. MEG selectively detects tangential sources. EEG measures both radial and tangential activity, although the radial components dominate the EEG signals at the scalp. Thus, while EEG provides more comprehensive information, it is more complicated to model due to considerable influences of the shape and conductivity of the volume conductor. Dipole localization techniques favor MEG due to the higher accuracy of MEG source localization compared to EEG when using the standard spherical head shape model. However, if special care is taken to address the above issues and enhance the EEG, the localization accuracy of EEG and MEG actually are comparable, although these surface EEG analytic techniques are not typically approved for clinical use in the United States. MEG dipole analysis is approved for clinical use and thus gives information that otherwise usually requires invasive intracranial EEG monitoring. There are only a few dozen whole head MEG units in operation in the world. While EEG is available in every hospital, specialized EEG laboratories capable of source localization techniques are nearly as scarce as MEG facilities. The combined use of whole-head MEG systems and multichannel EEG in conjunction with advanced source modeling techniques is an area of active development and will allow a better noninvasive characterization of the irritative zone in presurgical epilepsy evaluation. Finally, additional information on epilepsy may be gathered by either MEG or EEG analysis of data beyond the usual bandwidths used in clinical practice, namely by analysis of activity at high frequencies and near-DC activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Model Studies of the Magnetocardiogram
Grynszpan, F., & Geselowitz, D. B. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86034-5 · Cited by 226 · cited 1×
“The ECD is not a physical point, but it represents the activity of a small collection of synchronously firing neurons (Grynszpan and Geselowitz, 1973).”
BackgroundEEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Neuromagnetic functional localization: principles, state of the art, and perspectives
Romani, G. L., & Rossini, P. (1988) · Brain Topography · doi:10.1007/bf01129335 · Cited by 51
Cited by
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
Tallgren, P., Vanhatalo, S., Kaila, K., & Voipio, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.10.001 · Cited by 344
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Herbet, G., & Duffau, H. (2020) · Physiological Reviews · doi:10.1152/physrev.00033.2019 · Cited by 295
Metadata
- Authors
- Barkley, G. L., & Baumgartner, C.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-05
- Volume
- 20
- Issue
- 3
- Pages
- 163-178
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2042578958
- Cited by
- 202
- References
- 5
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MEG and EEG in Epilepsy. https://app.cochat.ai/papers/10.1097/00004691-200305000-00002
- The paper
- Barkley, G. L., & Baumgartner, C. (2003). MEG and EEG in Epilepsy. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-200305000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.