Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Identification and classification of the causes of events in transfusion medicine

Kaplan, H., Battles, J.B., Van der Schaaf, T.W., Shea, C.E., Mercer, S. Q. · 1998 · Transfusion

Abstract

BACKGROUND: Transfusion medicine lacks a standard method for the systematic collection and analysis of event reports. Review of event reports from the Food and Drug Administration (FDA) showed a relative paucity of information on event causation. Thus, a causal analysis method was developed as part of a prototype Medical Event Reporting System for Transfusion Medicine (MERS‐TM). STUDY DESIGN AND METHODS: MERS‐TM functions within existing quality assurance systems and utilizes descriptive coding and causal classification schemes. The descriptive classification system, based upon current FDA coding, was modified to meet participant needs. The Eindhoven Classification Model (Medical Version) was adopted for causal classification and analysis. Inter‐rater reliability for the MERS‐TM and among participating organizations was performed with the development group in the United States and with a safety science research group in the Netherlands. The MERS‐TM was then tested with events reported by participants. RESULTS: Data from 503 event reports from two blood centers and two transfusion services are discussed. The data showed multiple causes for events and more latent causes than previously recognized. The distribution of causes was remarkably similar to that in an industrial setting outside of medicine that uses the same classification approach. There was a high degree of inter‐rater reliability when the same events were analyzed by quality assurance personnel in different participating organizations. These personnel found the method practical and useful for providing new insights into conditions producing undesired events. CONCLUSION: A generally applicable and reliable method for identifying and quantifying problems that exist throughout transfusion medicine will be a valuable addition to event reporting activity. By using a common taxonomy, participants can compare their experience with that of others. If proven as readily implementable and useful as shown in initial studies, MERS‐TM is a potential standard for transfusion medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1537-2995.1998.38111299056319.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 166

Metadata

Authors
Kaplan, H., Battles, J. B., Van der Schaaf, T. W., Shea, C. E., & Mercer, S. Q.
Venue
Transfusion
Publisher
Wiley
Published
1998-11-12
Volume
38
Issue
11-12
Pages
1071-1081
ISSN
  • 0041-1132 (ISSN-L)
  • 1537-2995
OpenAlex
W2105711453
Cited by
166
References
2
FWCI
12.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification and classification of the causes of events in transfusion medicine. https://app.cochat.ai/papers/10.1046/j.1537-2995.1998.38111299056319.x
The paper
Kaplan, H., Battles, J. B., Van der Schaaf, T. W., Shea, C. E., & Mercer, S. Q. (1998). Identification and classification of the causes of events in transfusion medicine. Transfusion. https://doi.org/10.1046/j.1537-2995.1998.38111299056319.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.