Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 276

The DOI matches its Crossref record.

Problems of Heart Rate Correction in Assessment of Drug‐Induced QT Interval Prolongation

MALIK, MAREK·2001·Journal of Cardiovascular Electrophysiology

Abstract

Problems of Drug‐Prolonged QTc Assessment. Introduction: Estimation of QT interval prolongation belongs to safety assessment of every drug. Among unresolved issues, heart rate correction of the QT interval may be problematic. This article proposes a strategy for heart rate correction in drug safety studies and demonstrates the strategy using a study of ebastine, a nonsedating antihistamine. Methods and Results: Four‐way cross‐over Phase I study investigated 32 subjects on placebo, ebastine 60 mg once a day, 100 mg once a day, and terfenadine 180 mg twice a day. Repeated ECGs were obtained before each arm and after 7 days of treatment. The changes in heart rate‐corrected QTc interval were investigated using (A) 20 published heart rate correction formulas, (B) a correction formula optimized by QT/RR regression modeling in all baseline data, and (C) individual corrections optimized for each subject by drug‐free QT/RR regression modeling. (A) Previously published correction formulas found QTc interval increases on terfenadine. The results with ebastine were inconsistent. For instance, Bazett's and Lecocq's correction found significant QTc increase and decrease on ebastine, respectively. The results were related (|r| > 0.95) to the success of each formula (independence of drug‐free QTc and RR intervals). (B) The pooled drug‐free QT/RR regression found an optimized correction QTc = QT/RR 0.314. QTc interval changes on placebo, ebastine 60 mg, ebastine 100 mg, and terfenadine were − 1.95 ± 6.87 msec (P = 0.18), − 3.91 ± 9.38 msec (P = 0.053), 0.75 ± 8.23 msec (P = 0.66), and 12.95 ± 14.64 msec (P = 0.00025), respectively. (C) Individual QT/RR regressions were significantly different between subjects and found optimized corrections QTc = QT/RR α with α= 0.161 to 0.417. Individualized QTc interval changes on placebo, ebastine 60 mg, ebastine 100 mg, and terfenadine were − 2.76 ± 5.51 msec (P = 0.022), − 3.15 ± 9.17 msec (P = 0.11), − 2.61 ± 9.55 msec (P = 0.19), and 12.43 ± 15.25 msec (P = 0.00057), respectively. Drug‐unrelated QTc changes up to 4.70 ± 8.92 msec reflected measurement variability. Conclusion: Use of published heart rate correction formulas in the assessment of drug‐induced QTc prolongation is inappropriate, especially when the drug might induce heart rate changes. Correction formulas optimized for pooled drug‐free data are inferior to the formulas individualized for each subject. Measurement imprecision and natural variability can lead to mean QTc interval changes of 4 to 5 msec in the absence of drug treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2001.00411.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 276

Metadata

Authors
MALIK, M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2001-04
Volume
12
Issue
4
Pages
411-420
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2159163894
Cited by
276
References
0
FWCI
10.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Problems of Heart Rate Correction in Assessment of Drug‐Induced QT Interval Prolongation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2001.00411.x
The paper
MALIK, M. (2001). Problems of Heart Rate Correction in Assessment of Drug‐Induced QT Interval Prolongation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2001.00411.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.