The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Which QT Correction Formulae to Use for QT Monitoring?
Open accessAbstract
Background: Drug safety precautions recommend monitoring of the corrected QT interval. To determine which QT correction formula to use in an automated QT ‐monitoring algorithm in our electronic medical record, we studied rate correction performance of different QT correction formulae and their impact on risk assessment for mortality. Methods and Results: All electrocardiograms ( ECG s) in patients >18 years with sinus rhythm, normal QRS duration and rate <90 beats per minute (bpm) in the University Hospitals of Leuven (Leuven, Belgium) during a 2‐month period were included. QT correction was performed with Bazett, Fridericia, Framingham, Hodges, and Rautaharju formulae. In total, 6609 patients were included (age, 59.8±16.2 years; 53.6% male and heart rate 68.8±10.6 bpm). Optimal rate correction was observed using Fridericia and Framingham; Bazett performed worst. A healthy subset showed 99% upper limits of normal for Bazett above current clinical standards: men 472 ms (95% CI , 464–478 ms) and women 482 ms (95% CI 474–490 ms). Multivariate Cox regression, including age, heart rate, and prolonged QT c, identified Framingham (hazard ratio [ HR ], 7.31; 95% CI , 4.10–13.05) and Fridericia ( HR , 5.95; 95% CI , 3.34–10.60) as significantly better predictors of 30‐day all‐cause mortality than Bazett ( HR , 4.49; 95% CI , 2.31–8.74). In a point‐prevalence study with haloperidol, the number of patients classified to be at risk for possibly harmful QT prolongation could be reduced by 50% using optimal QT rate correction. Conclusions: Fridericia and Framingham correction formulae showed the best rate correction and significantly improved prediction of 30‐day and 1‐year mortality. With current clinical standards, Bazett overestimated the number of patients with potential dangerous QT c prolongation, which could lead to unnecessary safety measurements as withholding the patient of first‐choice medication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atypical antipsychotic drugs and the risk of sudden cardiac death
Ray, W. A., Chung, C. P., Murray, K. T., Hall, K., & Stein, C. M. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0806994 · Cited by 1,194
Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei Herzkranken
FRIDERICIA, L. S. (1920) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1920.tb18266.x · Cited by 1,000
Drew, B. J., Ackerman, M. J., Funk, M., Gibler, W. B., Kligfield, P., Menon, V., Philippides, G. J., Roden, D. M., & Zareba, W. (2010) · Circulation · doi:10.1161/circulationaha.109.192704 · Cited by 821
An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study)
Sagie, A., Larson, M. G., Goldberg, R. J., Bengtson, J. R., & Levy, D. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90562-d · Cited by 715
QT interval prolongation predicts cardiovascular mortality in an apparently healthy population.
Schouten, E. G., Dekker, J. M., Meppelink, P., Kok, F. J., Vandenbroucke, J. P., & Pool, J. (1991) · Circulation · doi:10.1161/01.cir.84.4.1516 · Cited by 630
QT Interval: How to Measure It and What Is “Normal”
GOLDENBERG, I., MOSS, A. J., & ZAREBA, W. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00408.x · Cited by 535
Clinical Decision-Support Systems
Musen, M. A., Middleton, B., & Greenes, R. A. (2014) · Biomedical Informatics · doi:10.1007/978-1-4471-4474-8_22 · Cited by 483
Luo, S., Michler, K., Johnston, P., & Macfarlane, P. W. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.030 · Cited by 454
Malik, M., Färbom, P., Batchvarov, V, Hnatkova, K., & Camm, A. J. (2002) · Heart · doi:10.1136/heart.87.3.220 · Cited by 436
Darpo, B., Nebout, T., & Sager, P. T. (2006) · The Journal of Clinical Pharmacology · doi:10.1177/0091270006286436 · Cited by 319
Cited by
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac244 · Cited by 3,076
Herrmann, J., Lenihan, D., Armenian, S., Barac, A., Blaes, A., Cardinale, D., Carver, J., Dent, S., Ky, B., Lyon, A. R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab674 · Cited by 645
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeac106 · Cited by 507
Saleh, M., Gabriels, J., Chang, D., Soo Kim, B., Mansoor, A., Mahmood, E., Makker, P., Ismail, H., Goldner, B., Willner, J., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.008662 · Cited by 340
Shah, S. A., Szeto, A. H., Farewell, R., Shek, A., Fan, D., Quach, K. N., Bhattacharyya, M., Elmiari, J., Chan, W., O'Dell, K., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.011318 · Cited by 111
Metadata
- Authors
- Vandenberk, B., Vandael, E., Robyns, T., Vandenberghe, J., Garweg, C., Foulon, V., Ector, J., & Willems, R.
- Venue
- Journal of the American Heart Association
- Published
- 2016-06-13
- Volume
- 5
- Issue
- 6
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2435493985
- Cited by
- 404
- References
- 23
- FWCI
- 22.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Which QT Correction Formulae to Use for QT Monitoring? https://app.cochat.ai/papers/10.1161/jaha.116.003264
- The paper
- Vandenberk, B., Vandael, E., Robyns, T., Vandenberghe, J., Garweg, C., Foulon, V., Ector, J., & Willems, R. (2016). Which QT Correction Formulae to Use for QT Monitoring? Journal of the American Heart Association. https://doi.org/10.1161/jaha.116.003264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.