Irrigated‐Tip Catheter Ablation of Pulmonary Veins for Treatment of Atrial Fibrillation
The DOI matches its Crossref record.
Abstract
Irrigated‐Tip Catheter Ablation of PVs. Introduction: Catheter ablation of pulmonary veins (PV) for treatment of atrial fibrillation (AF) is limited by the disparate requirements of sufficient energy delivery to achieve PV isolation while avoiding PV stenosis. The aim of the present study was to evaluate the safety and efficacy of using an irrigated‐tip catheter for systematic isolation of PV. Methods and Results: The study population consisted of 136 consecutive patients (109 men, mean age 52 ± 10 years) with symptomatic, drug‐refractory paroxysmal (122) or persistent (14) AF. Cavotricuspid isthmus ablation and systematic radiofrequency isolation of all four PVs (guided by a circumferential mapping catheter) was performed in all patients with a protocol using an irrigated‐tip catheter. PV diameter was assessed by selective angiography. The electrophysiologic endpoint of PV isolation was achieved in 100% of patients. Bidirectional cavotricuspid isthmus block was achieved in 99% of patients. Moderate PV stenosis (50% narrowing) was observed in one patient (0.7%) without clinical consequence. No other complications were observed. Reablation procedures were required in 67 patients (49%). After a mean follow‐up of 8.8 ± 5.3 months, 81% of patients were free of AF clinical recurrence, including 66% not taking any antiarrhythmic drugs. Conclusion: Systematic radiofrequency ablation of PV using an irrigated‐tip catheter in patients with atrial fibrillation allows complete isolation of all four PVs with a very low incidence of stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The clinical implications of endothelial dysfunction
Widlansky, M. E., Gokce, N., Keaney, J. F., & Vita, J. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00994-x · Cited by 1,749
Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Catheter Ablation for Atrial Fibrillation
Weerasooriya, R., Khairy, P., Litalien, J., Macle, L., Hocini, M., Sacher, F., Lellouche, N., Knecht, S., Wright, M., Nault, I., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.061 · Cited by 737
Self-citationReversal of Left Ventricular Dysfunction Following Ablation of Atrial Fibrillation
GENTLESK, P. J., SAUER, W. H., GERSTENFELD, E. P., LIN, D., DIXIT, S., PA‐C, E. Z., CALLANS, D., & MARCHLINSKI, F. E. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00653.x · Cited by 276
Metadata
- Authors
- MACLE, L., JAÏS, P., WEERASOORIYA, R., HOCINI, M., SHAH, D. C., CHOI, K., SCAVÉE, C., RAYBAUD, F., CLÉMENTY, J., & HAÏSSAGUERRE, M.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 13
- Issue
- 11
- Pages
- 1067-1073
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2046173808
- Cited by
- 151
- References
- 0
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Irrigated‐Tip Catheter Ablation of Pulmonary Veins for Treatment of Atrial Fibrillation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2002.01067.x
- The paper
- MACLE, L., JAÏS, P., WEERASOORIYA, R., HOCINI, M., SHAH, D. C., CHOI, K., SCAVÉE, C., RAYBAUD, F., CLÉMENTY, J., & HAÏSSAGUERRE, M. (2002). Irrigated‐Tip Catheter Ablation of Pulmonary Veins for Treatment of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2002.01067.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.