The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Analysis of Implantable Cardioverter Defibrillator Therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial
Abstract
Introduction: The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood. Methods and Results: The therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow‐up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia. Conclusion: Delivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided. (J Cardiovasc Electrophysiol, Vol. 14, pp. 940‐948, September 2003)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · cited 4×
“All therapies 157 (8) 734 (36) 253 (12) 59 (3) 37 (2) 5 (0) 812 (39)”
InfluentialEpstein, A. E., Miles, W. M., Benditt, D. G., Camm, A. J., Darling, E. J., Friedman, P. L., Garson, A., Harvey, J. C., Kidwell, G. A., Klein, G. J., et al. (1996) · Circulation · doi:10.1161/01.cir.94.5.1147 · Cited by 220
Self-citationMotor vehicle accidents in patients with an implantable cardioverter-defibrillator
Curtis, A. B., Conti, J. B., Tucker, K. J., Kubilis, P. S., Reilly, R. E., & Woodard, D. A. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00133-k · Cited by 77
Cited by
WILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03625.x · Cited by 835
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
Inappropriate Implantable Cardioverter-Defibrillator Shocks
van Rees, J. B., Borleffs, C. J. W., de Bie, M. K., Stijnen, T., van Erven, L., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.059 · Cited by 451
Raitt, M. H., Connor, W. E., Morris, C., Kron, J., Halperin, B., Chugh, S. S., McClelland, J., Cook, J., MacMurdy, K., Swenson, R., et al. (2005) · JAMA · doi:10.1001/jama.293.23.2884 · Cited by 371
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Self-citation
Metadata
- Authors
- KLEIN, R. C., RAITT, M. H., WILKOFF, B. L., BECKMAN, K. J., COROMILAS, J., WYSE, D. G., FRIEDMAN, P. L., MARTINS, J. B., EPSTEIN, A. E., HALLSTROM, A. P., LEDINGHAM, R. B., BELCO, K. M., GREENE, H. L., & The Avid Investigators
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2003-09
- Volume
- 14
- Issue
- 9
- Pages
- 940-948
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2012508269
- Cited by
- 179
- References
- 4
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.