Abstract

Introduction: Although numerous trials have shown benefit of implantable cardioverter defibrillators (ICDs) for either primary or secondary prevention, no trial has prospectively enrolled patients from both indications and analyzed ICD utilization between groups. Methods and Results: We performed a retrospective review of MIRACLE ICD, a randomized, prospective double‐blind trial of cardiac resynchronization therapy (CRT) in the ICD population. Both secondary prevention (N = 563) and primary prevention patients (N = 415) were enrolled. Subgroup analysis for frequency of ventricular tachycardia (VT) and ventricular fibrillation (VF) episodes and detection accuracy revealed that primary prevention patients had a significantly lower frequency of appropriate episodes (0.09 vs 0.43 episodes/month) at significantly faster cycle lengths (303 ± 54 ms vs 366 ± 71 ms, P < 0.0001). These episodes were more likely to be classified as VF by the device and thus receive shock therapy (42% by device classification vs 19% in secondary prevention, P < 0.0001). The absolute rate of inappropriate detections in the primary prevention group per month of follow‐up was lower but constituted a much higher proportion of all episodes (30% vs 14%, P < 0.0001). Most inappropriate detections in the secondary prevention group were due to rapidly conducted atrial fibrillation; most in the primary prevention patients were due to sinus tachycardia. Conclusion: Patients receiving an ICD for CRT therapy with primary prevention indications have a different clinical arrhythmia course than patients with a history of spontaneous VT/VF. This has implications for the optimal programming of ICDs. Longer‐term, prospective evaluation of these differences is warranted and should be investigated in the broader ICD patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03625.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 835

Metadata

Authors
WILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-08-26
Volume
15
Issue
9
Pages
1002-1009
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2062316006
Cited by
835
References
3
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.