Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Left Atrial Isthmus: Anatomic Aspects Relevant for Linear Catheter Ablation Procedures in Humans

BECKER, ANTON E. · 2004 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: The success rate of catheter maze ablation procedures for atrial fibrillation depends upon adequate electrical isolation by performing linear ablation lesions. However, recurrence of atrial arrhythmias is not uncommon, particularly in the so‐called left atrial isthmus, between the orifice of the left inferior pulmonary vein and the mitral valve annulus. The focus of the present study is the anatomy of this area. Methods and Results: Twenty human hearts were studied. The distance between the left inferior pulmonary vein and the mitral valve, the thickness of the left atrial myocardium, and the extent of left atrial myocardium toward the mitral valve were measured. The AV groove contained a fat pad harboring the great cardiac vein. The distance between the vein and the valve varied considerably (range 17–51 mm). The great cardiac vein coursed along the inferior left atrial wall, approximately 1 cm above the level of the mitral valve. Myocardial thickness also varied considerably (distal: range 1.4–7.7 mm, midway: range 1.2–4.4 mm, proximal: range 0−3.2 mm). Left atrial myocardium extended onto the mitral valve in two hearts, and the left atrial myocardium ended above the level of the mitral valve (range 1.8−5.1 mm) in six hearts. An important variable because it raises the question of how much energy should be used—and at which point—to achieve an adequate transmural ablation line. Conclusion: The great cardiac vein is not an adequate marker for the level of the mitral valve, left atrial myocardium may continue onto the mitral valve, the distance between the left inferior pulmonary vein and mitral valve varies considerably, and left atrial myocardial thickness is highly variable and not uniform.(J Cardiovasc Electrophysiol, Vol. 15, pp. 809‐812, July 2004)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.03651.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 180

Metadata

Authors
BECKER, A. E.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-07
Volume
15
Issue
7
Pages
809-812
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1551564600
Cited by
180
References
3
FWCI
8.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Atrial Isthmus: Anatomic Aspects Relevant for Linear Catheter Ablation Procedures in Humans. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03651.x
The paper
BECKER, A. E. (2004). Left Atrial Isthmus: Anatomic Aspects Relevant for Linear Catheter Ablation Procedures in Humans. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03651.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.