The DOI matches its Crossref record.
Efficacy of Repeat Pulmonary Vein Isolation Procedures in Patients with Recurrent Atrial Fibrillation
Abstract
Introduction: Pulmonary vein (PV) isolation is effective in the treatment of most patients with atrial fibrillation (AF). Some advocate the addition of linear ablation techniques to improve efficacy; however, previous studies suggest recurrent PV conduction is responsible for AF recurrence. The aim of this study was to determine the effectiveness of repeat PV isolation in patients with recurrent AF after an initial ablation procedure and to determine if any patient characteristics predict failure of repeat PV isolation procedures. Methods and Results: Seventy‐four patients with two or more AF ablation procedures using selective PV isolation were included. PV isolation was guided with multielectrode ring catheter recordings, electroanatomic mapping, and intracardiac electrocardiography. Radiofrequency energy was delivered using a 4‐mm‐tip catheter (maximum 40 W, 52°C); cooled‐tip ablation was performed in 10 patients. Linear ablation was not performed. Antiarrhythmic drugs were continued for at least 6 weeks after ablation; AF episodes during this period were censored. Reconnection of one or more segments of previously ablated PVs was observed in 97% of patients; reconnected PVs served as the trigger for AF in 77%. Repeat PV isolation resulted in AF control (cure or 90% reduction in AF episodes) in 64 patients (86%) over a follow‐up period of 9.1 ± 6.7 months. “High‐risk” characteristics such as left atrial enlargement, persistent AF, or mitral regurgitation did not predict failure of repeat PV isolation procedures. Conclusion: Recurrent AF following selective PV isolation is overwhelmingly associated with PV electrical reconnection. Repeat PV isolation without linear ablation provides effective treatment for recurrent AF in patients in whom an initial PV isolation procedure failed, independent of clinical characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationKuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
PIORKOWSKI, C., KOTTKAMP, H., TANNER, H., KOBZA, R., NIELSEN, J. C., ARYA, A., & HINDRICKS, G. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00245.x · Cited by 110
Metadata
- Authors
- CALLANS, D. J., GERSTENFELD, E. P., DIXIT, S., ZADO, E., VANDERHOFF, M., REN, J., & MARCHLINSKI, F. E.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2004-08-26
- Volume
- 15
- Issue
- 9
- Pages
- 1050-1055
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2074149850
- Cited by
- 291
- References
- 0
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of Repeat Pulmonary Vein Isolation Procedures in Patients with Recurrent Atrial Fibrillation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.04052.x
- The paper
- CALLANS, D. J., GERSTENFELD, E. P., DIXIT, S., ZADO, E., VANDERHOFF, M., REN, J., & MARCHLINSKI, F. E. (2004). Efficacy of Repeat Pulmonary Vein Isolation Procedures in Patients with Recurrent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.04052.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.