Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation
Abstract
BACKGROUND: The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. METHODS: Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. RESULTS: A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30-40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. CONCLUSIONS: The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Symptomatic and asymptomatic atrial fibrillation recurrences are frequent after catheter ablation.
“Patient should also be aware that symptomatic and asymptomatic AF recurrences are frequent after catheter ablation.119,781,782”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [781]
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040 · see citing works
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018 · see citing works
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896 · see citing works
Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation
Pappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., DICANDIA, C. D., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 855 · see citing works
Characterization of Different Subsets of Atrial Fibrillation in General Practice in France
Lévy, S., Maarek, M., Coumel, P., Guize, L., Lekieffre, J., Medvedowsky, J. L., & Sebaoun, A. (1999) · Circulation · doi:10.1161/01.cir.99.23.3028 · Cited by 580 · see citing works
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 478 · see citing works
Callans, D. J., Gerstenfeld, E. P., Dixit, S., Zado, E. S., Vanderhoff, M., Ren, J., & Marchlinski, F. E. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04052.x · Cited by 289 · see citing works
Modification of the Substrate for Maintenance of Idiopathic Human Atrial Fibrillation
Ernst, S., Schlüter, M., Ouyang, F. O., Khanedani, A., Cappato, R., Hebe, J., Volkmer, M., Antz, M., & Kück, K. (1999) · Circulation · doi:10.1161/01.cir.100.20.2085 · Cited by 203 · see citing works
Kottkamp, H., Tanner, H., Kobza, R., Schirdewahn, P., Dorszewski, A., Gerds‐Li, J., Carbucicchio, C., Piorkowski, C., & Hindricks, G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.049 · Cited by 196 · see citing works
Self-citationClinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers
Gerstenfeld, E. P., Guerra, P. G., SPARKS, P. B., Hattori, K., & Lesh, M. D. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00900.x · Cited by 191 · see citing works
Specific linear left atrial lesions in atrial fibrillation
Kottkamp, H., Hindricks, G., Autschbach, R., Krauss, B., Strasser, B., Schirdewahn, P., Fabricius, A., Schuler, G. C., & Mohr, F. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01993-9 · Cited by 170 · see citing works
Self-citationAsymptomatic or “Silent” Atrial Fibrillation
Page, R. L., Tilsch, T. W., Connolly, S. J., Schnell, D., Marcello, S. R., Wilkinson, W. E., & Pritchett, E. L. C. (2003) · Circulation · doi:10.1161/01.cir.0000051455.44919.73 · Cited by 165 · see citing works
Razavi, M., Zhang, S., Yang, D., Sanders, R. A., Kar, B., Delapasse, S., Ai, T., Moreira, W., Olivier, B., Khoury, D. S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50048.x · Cited by 154 · see citing works
Oral, H., Veerareddy, S., Good, E. D., HALL, B. W., Cheung, P. W., Tamirisa, K. P., Han, J. D., Fortino, J., Chugh, A., Bogun, F. M., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04055.x · Cited by 119 · see citing works
Berkowitsch, A. (2003) · EP Europace · doi:10.1016/s1099-5129(03)00089-8 · Cited by 45 · see citing works
Asymptomatic Atrial Fibrillation in Symptomatic Patients
Callans, D. J. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04345.x · Cited by 16 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418 · see citing works
Self-citation2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403 · see citing works
Self-citationRadiofrequency ablation as initial therapy in paroxysmal atrial fibrillation
Cosedis Nielsen, J., Johannessen, A., Raatikainen, P., Hindricks, G., Walfridsson, H., Kongstad, O., Pehrson, S., Englund, A., Hartikainen, J., Mortensen, L. S., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113566 · Cited by 720 · see citing works
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362 · see citing works
Kirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · Europace · doi:10.1093/europace/eum191 · Cited by 293 · see citing works
Self-citationHanke, T., Charitos, E. I., Stierle, U., Karluss, A., Kraatz, E., Graf, B., Hagemann, A., Misfeld, M., & Sievers, H. H. (2009) · Circulation · doi:10.1161/circulationaha.108.838474 · Cited by 121 · see citing works
New devices for very long-term ECG monitoring
Lobodzinski, S. S., & Laks, M. M. (2012) · Cardiology Journal · doi:10.5603/cj.2012.0039 · Cited by 106 · see citing works
- Authors
- PIORKOWSKI, C., KOTTKAMP, H., TANNER, H., KOBZA, R., NIELSEN, J. C., ARYA, A., & HINDRICKS, G.
- Affiliations
- Leipzig University (DE)
- Corresponding author
- PIORKOWSKI, CHRISTOPHER
- ORCID
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-12
- Volume
- 16
- Issue
- 12
- Pages
- 1286-1292
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2004014039
- Cited by
- 110
- References
- 16
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 7 · 2015: 6 · 2014: 5 · 2013: 5 · 2012: 13
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Cardiovascular Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- BORIS (University Library Bern) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, catheter ablation, circumferential pulmonary vein ablation, follow-up strategy, remote monitoring, sinus rhythm maintenance
- MeSH terms
- Atrial Fibrillation, Clinical Trials as Topic, Electrocardiography, Female, Follow-Up Studies, Germany, Humans, Male, Middle Aged, Prospective Studies, Pulmonary Veins, Telemetry, Time Factors, Electrocardiography, Ambulatory, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review