Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker Leads

Open access
VAN ROODEN, CORNELIS J., MOLHOEK, SANDER G., ROSENDAAL, FRITS R., SCHALIJ, MARTIN J., MEINDERS, A. EDO, HUISMAN, MENNO V.·2004·Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Pacemaker lead implantation can cause thrombosis, which can be associated with serious local morbidity and complicated by pulmonary embolism. Few reliable estimates of the incidence of thrombosis have been reported. The contribution of established risk factors to venous thrombosis in patients with implanted pacemaker leads is unknown. Methods and Results: One hundred forty‐five consecutive patients n = 145) underwent routine clinical and Doppler ultrasound evaluation for thrombosis before and 3, 6, and 12 months after lead implantation. Established risk factors for venous thrombosis were assessed in detail for all patients. Clinical outcome, including clinically manifest thrombosis, pulmonary embolism, associated pacemaker lead infection, complicated reinterventions, and death, was evaluated. Thrombosis was observed in 34 (23%) of 145 patients. Thrombosis did not cause any signs or symptoms in 31 patients but resulted in overt clinical symptoms in 3 patients. The absence of anticoagulant therapy, use of hormone therapy, and a personal history of venous thrombosis were associated with an increased risk of thrombosis. The risk of thrombosis increased in the presence of multiple pacemaker leads compared to a single lead. Conclusion: Established risk factors for venous thrombosis and the presence of multiple pacemaker leads contribute substantially to the occurrence of thrombosis associated with permanent pacemaker leads. Risk factor assessment prior to implantation may be useful for identifying patients at risk for thrombotic complications. Preventive management in these patients is warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2004.04081.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 190

Metadata

Authors
VAN ROODEN, C. J., MOLHOEK, S. G., ROSENDAAL, F. R., SCHALIJ, M. J., MEINDERS, A. E., & HUISMAN, M. V.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2004-11
Volume
15
Issue
11
Pages
1258-1262
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2166070087
Cited by
190
References
1
FWCI
3.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker Leads. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.04081.x
The paper
VAN ROODEN, C. J., MOLHOEK, S. G., ROSENDAAL, F. R., SCHALIJ, M. J., MEINDERS, A. E., & HUISMAN, M. V. (2004). Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker Leads. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.04081.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.