Optimal sensor placement of bridge structure based on sensitivity‐effective independence method
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Taking the optimal sensor placement problem in bridge structural health monitoring as the study object and relying on the engineering example of a simply supported steel truss bridge, the improved optimal sensor placement method based on sensitivity‐effective independence method was proposed. Using the sensitivity coefficient reflecting structural damage, the proposed method could modify the effective independence method reflecting the maximum linear independence. The proposed method further optimizes the sensor placement method. A method for selecting the number of models based on modal closeness was proposed and makes the selection of the number of modes more objective. The example analysis shows that evaluations using this method are effective for multiple evaluation criteria. The method ensures observability of the mode vector and identifiability of structural damage. It is an effective optimal sensor placement algorithm for the bridge structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various research suggests a list of characteristics an optimised sensor network needs to meet, including being capable of returning accurate information about the structure continuously, sensitive to low damage levels and different types of faults, robust to changes in condition parameters, measurement noise, and environmental effects, and an economically lower installation and monitoring cost [24”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [125]
In the citing paper
“Nonetheless, the configuration determined by SEFI placed sensors at the two ends of the damaged node, whereas EFI and the sensitivity coefficient method only used one end node each.”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [125]
In the citing paper
“The studies that first introduced these modified EFI methods provided comparative analyses that showcased higher levels of accuracy than those of EFI [125,136,139].”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [125]
In the citing paper
“As the presence of structural damage leads to significant changes in the geometry of a structure, Chai et al. [125] propose an alternative modification to EFI such that it could respond more instantaneously to any structural changes due to new damages in the structure to be studied.”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [125]
In the citing paper
“Regarding its accuracy for the targeted 40 mode shapes, the errors under the two criteria from the configuration produced by SEFI were discovered to be the least in comparison with EFI and the sensitivity coefficient method.”
From Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review (2025) · cites this paper as [125]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Research works printed but not linked: 27
- 10.1007/s13349-017-0254-3 · DOI
- 10.1016/j.apm.2020.05.021 · DOI
- 10.1080/15732479.2018.1438483 · DOI
- 10.1177/1077546315582122 · DOI
- 10.1111/mice.12122 · DOI · Paper page
- 10.1177/107754602029204 · doi:10.1177/107754602029204
- Wu X., 2017, Optimal sensor placement for a truss structure using particle swarm optimisation algorithm, Int. J. Acoust. Vib, 22, 439
- 10.1007/s12206-015-0606-z · DOI
- 10.1016/j.engappai.2016.03.002 · DOI
- 10.1007/s00158-018-2024-1 · DOI
- 10.1088/1361-665X/aa7930 · DOI
- 10.1080/19942060.2018.1482476 · DOI
- 10.1111/str.12128 · DOI
- 10.1109/ACCESS.2018.2869632 · DOI
- 10.1016/j.ymssp.2013.06.022 · DOI
- 10.1002/tal.712 · DOI · Paper page
- 10.1016/j.jsv.2007.05.004 · DOI · Paper page
- 10.1002/stc.1707 · DOI · Paper page
- 10.1007/s12065-020-00372-1 · DOI · Paper page
- 10.1002/stc.1708 · DOI · Paper page
- 10.1002/stc.1664 · DOI · Paper page
- 10.1088/0964-1726/24/12/125034 · DOI · Paper page
- Sun X., 2015, Optimal placement of multi‐type sensor based on sensitivity for plate structures, Eng. Mech, 32, 77
- 10.1007/s00366-018-0613-7 · DOI
- 10.1016/j.neucom.2018.03.088 · DOI
- 10.21595/jve.2017.18206 · DOI
- Tian H., 2017, A direct way for the sensitivity analysis of modal assurance criterion of a sliding machine working table, Multimodel. Mater. Struct, 13, 135
Cited by
Optimal Sensor Placement for Structural Health Monitoring: A Comprehensive Review
Sun, Z., Mahmoodian, M., Sidiq, A., Jayasinghe, S., Shahrivar, F., & Setunge, S. (2025) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan14020022 · Cited by 53
“In each iteration of the EI, the independence distribution vector E D is determined based on Equation (7), where Ψ A and λ are the eigenvector and eigenvalue for the contribution of each DOF, respectively [125].”
Influential
Metadata
- Authors
- Chai, W., Yang, Y., Yu, H., Yang, F., & Yang, Z.
- Affiliations
- School of Highway Chang'an University Xi'an People's Republic of China
- School of Civil Engineering Shaan'xi Vocational and Technical College Xi'an People's Republic of China
- ORCID
- Yang, Yaxun
- Venue
- IET Circuits, Devices & Systems
- Published
- 2021-05-11
- Volume
- 16
- Issue
- 2
- Pages
- 125-135
- ISSN
- 1751-858X
- Cited by
- 19
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.