CoChat

Comparative study of current vector control performance of alternate fault tolerant inverter topologies for three-phase pm brushless ac machine with one phase open circuit fault

Hoang, K.D., Foster, M.P., Stone, D.A., Zhu, Z.Q. · 2010 · 5th IET International Conference on Power Electronics, Machines and Drives (PEMD 2010)
Cited by 42

The DOI matches its Crossref record.

Abstract

Reliability and fault tolerance of drive systems has received renewed research interest over last decade with several fault tolerant drive topologies and control schemes having been proposed and investigated. In this paper, the performance of hysteresis current vector control methodologies when applied to three common fault tolerant drive topologies has been investigated and compared theoretically and experimentally. Their advantages and limitations in terms of current value, current and torque ripples, and operating speed range etc. are considered and verified by both simulated and measured results. It is proven that by simply modifying the hysteresis current control methodology, the maximum torque per ampere (MTPA) can still be achieved in post-fault operation, albeit with potentially increased current value, low frequency current and torque ripples, and compromised speed operating range. (6 pages)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/cp.2010.0052

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 42

Metadata

Authors
Hoang, K. D., Foster, M. P., Stone, D. A., & Zhu, Z. Q.
Venue
5th IET International Conference on Power Electronics, Machines and Drives (PEMD 2010)
Published
2010
Pages
413-413
OpenAlex
W2008612001
Cited by
42
References
0
FWCI
6.11
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative study of current vector control performance of alternate fault tolerant inverter topologies for three-phase pm brushless ac machine with one phase open circuit fault. https://app.cochat.ai/papers/10.1049/cp.2010.0052
The paper
Hoang, K. D., Foster, M. P., Stone, D. A., & Zhu, Z. Q. (2010). Comparative study of current vector control performance of alternate fault tolerant inverter topologies for three-phase pm brushless ac machine with one phase open circuit fault. 5th IET International Conference on Power Electronics, Machines and Drives (PEMD 2010). https://doi.org/10.1049/cp.2010.0052

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.