Finite-Control-Set MPC for Open-Phase Fault-Tolerant Control of PM Synchronous Motor Drives
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A fault-tolerant permanent magnet synchronous motor drive is proposed in this article. The strategy is based on finite-control-set model-predictive control that is easy to implement and replaces the conventional proportional-integral controllers and pulsewidth modulators. A three-phase four-wire converter topology is used, which connects the neutral of the motor to the middle of the dc link in a capacitive divider. The main contribution of the proposed strategy relies on the fact that no reconfigurations or modifications of the converter topology and the controller strategy are required from normal operation to postfault operation. As a result, the transition from healthy to faulty state is smooth and not noticeable in the torque waveform. In addition, a simple fault detection method is derived by using the predicted variables. Experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy and show a pulsation-free torque on fault operation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The main advantage of this solution is that there is no need to converter topology modification after the fault detection and thus the transition from healthy to faulty state is smooth.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [323]
Citations
Cites
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“A simple possibility to allow more than one independent current flow also in faulty operation is by connecting the neutral point of the motor either to the middle of the VSI dc link [4] (a split capacitor bank is required) or to an extra inverter leg [5], as”
BackgroundDesign and Implementation of Model Predictive Control for Electrical Motor Drives
Bolognani, S., Bolognani, S., Peretti, L., & Zigliotto, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007547 · Cited by 452
Finite-Control-Set Model Predictive Torque Control With a Deadbeat Solution for PMSM Drives
Xie, W., Wang, X., Wang, F., Xu, W., Kennel, R. M., Gerling, D., & Lorenz, R. D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2410767 · Cited by 394 · cited 1×
“A deadbeat solution for an FCS-MPC in terms of the direct torque control was presented in [19].”
MethodExperimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Preindl, M., & Bolognani, S. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2227265 · Cited by 376 · cited 1×
“In [17], direct torque control of a PMSM using FCS-MPC was”
MethodPreindl, M., & Bolognani, S. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2220353 · Cited by 235 · cited 1×
“introduced for the maximum torque per ampere operation and in [18] for the field weakening operation.”
BackgroundControl Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Modeling and Control of Three-Phase PMSMs Under Open-Phase Fault
Gaeta, A., Scelba, G., & Consoli, A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2228614 · Cited by 151
Detection and Discrimination of Open Phase Fault in Permanent Magnet Synchronous Motor Drive System
Hang, J., Zhang, J., & Cheng, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2479399 · Cited by 115 · cited 1×
“A common fault arising directly in the motor, as well as in the associated voltage-source inverter (VSI), is the open-phase fault [1].”
BackgroundCost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault
Kontarcek, A., Bajec, P., Nemec, M., Ambrozic, V., & Nedeljkovic, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2437357 · Cited by 106 · cited 1×
“In [3], as a remedial strategy for the postfault operation to reduce the torque fluctuation, conventional field-oriented control”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [323] a FTC strategy based on a finite-controlset MPC was proposed for a three-phase four-wire converter topology of the PMSM drive which connects the neutral point of the motor to the middle of the DC-link capacitor.”
MethodData Mining Applications to Fault Diagnosis in Power Electronic Systems: A Systematic Review
Moradzadeh, A., Mohammadi‐Ivatloo, B., Pourhossein, K., & Anvari‐Moghaddam, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3131293 · Cited by 103
Feng, G., Lai, C., Li, W., Han, Y. Q., & Kar, N. C. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3019391 · Cited by 64
Model-Based Fault Diagnosis Algorithms for Robotic Systems
Hasan, A., Tahavori, M., & Midtiby, H. S. (2023) · IEEE Access · doi:10.1109/access.2022.3233672 · Cited by 46
“A possible algorithm for the fault-tolerant control is by using model predictive control (MPC) [14].”
MethodWang, X., Ren, S., Xiao, D., Meng, X., Fang, G., & Wang, Z. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3306457 · Cited by 47
“Digital Object Identifier 10.1109/TTE.2023.3306457 attracted significant attention in many fields, such as aerospace, electric vehicle, rail traction, and ship propulsion [1], [2], [3], [4], [5].”
BackgroundInfluential
Metadata
- Authors
- Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R.
- Affiliations
- Technische Hochschule Mittelhessen (DE)
- Universidad Nacional de Villa Mercedes (AR)
- Otto-von-Guericke-Universität Magdeburg (DE)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-06
- Volume
- 67
- Issue
- 6
- Pages
- 4444-4452
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2966061424
- Cited by
- 88
- References
- 21
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 16 · 2023: 13 · 2022: 15 · 2021: 19 · 2020: 13
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- Mittelhessen University of Applied Sciences, Germany
- National Scientific and Technical Research Council, Argentina
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- finite control set model predictive control, fault-tolerant control, permanent magnet synchronous motor drives, open-phase fault, capacitive divider, fault detection, torque ripple reduction, motor drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finite-Control-Set MPC for Open-Phase Fault-Tolerant Control of PM Synchronous Motor Drives. https://app.cochat.ai/papers/10.1109/tie.2019.2931285
- The paper
- Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R. (2020). Finite-Control-Set MPC for Open-Phase Fault-Tolerant Control of PM Synchronous Motor Drives. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2019.2931285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.