The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Body area network for wireless patient monitoring
Abstract
Patient data monitoring is a key issue for health and disease management. The use of wireless sensors within a body area network (BAN) makes this task seamless and easy. A BAN system is presented, which allows the connectivity of a wide range of heterogeneous body sensors to a portable hub device that is connectable to external networks (IEEE 802.11, GPRS). This BAN is based on the use of Zigbee/IEEE 802.15.4 standard technology and off-the-shelf modules. It is currently being used at the European level for the detection and the prediction of the human physiological state in relation to wakefulness, fatigue, and stress applications in which users carrying out daily activities are monitored in an unobtrusive and comfortable way. Characterised by its low power consumption, low cost, and ability to connect a wide range of heterogeneous sensors, this system can substantially improve the performance of different services, especially those that are health related.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
A lightweight multi-layer authentication protocol for wireless body area networks
Shen, J., Chang, S., Shen, J., Liu, Q., & Sun, X. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2016.11.033 · Cited by 258
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
Metadata
- Authors
- Montón, E., Hernandez, J. F., Blasco, J. M., Hervé, T., Micallef, J., Grech, I., Brincat, A., & Traver, V.
- Venue
- IET Communications
- Published
- 2008-02
- Volume
- 2
- Issue
- 2
- Pages
- 215-222
- ISSN
- 1751-8628 (ISSN-L)
- 1751-8636
- OpenAlex
- W2026623061
- Cited by
- 195
- References
- 1
- FWCI
- 11.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Body area network for wireless patient monitoring. https://app.cochat.ai/papers/10.1049/iet-com:20070046
- The paper
- Montón, E., Hernandez, J. F., Blasco, J. M., Hervé, T., Micallef, J., Grech, I., Brincat, A., & Traver, V. (2008). Body area network for wireless patient monitoring. IET Communications. https://doi.org/10.1049/iet-com%3A20070046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.