CoChat

Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity

Ebrahimi, B.M., Faiz, J. · 2010 · IET Electric Power Applications
Cited by 83

The DOI matches its Crossref record.

Abstract

Albeit permanent magnet synchronous motors (PMSMs) under static and dynamic eccentricity have been studied in few papers, so far mixed eccentricity has not been investigated. In this study, a novel index is introduced for dynamic and mixed eccentricity fault diagnosis in PMSM. This index is the amplitude of side-band components with a particular frequency pattern that is extracted from spectrum analysis of the motor torque. The index provides precise detection of the eccentricity occurrence, recognition of its type and determination of its degree. To evaluate the ability of the proposed index for the eccentricity diagnosis and estimation of its severity, first the correlation between indices, static and dynamic eccentricity degrees are calculated. The type of eccentricity is determined using k-nearest neighbour (KNN) classifier. At the next step, a three-layer artificial neural network is employed to estimate the eccentricity degree of torque profiles based on their type of eccentricity. After all, a white Gaussian noise is added to the simulated torque and robustness of the proposed index is analysed with respect to the noise variance. Meanwhile, the spectrum analysis of the stator current in faulty PMSM under static, dynamic and mixed eccentricities is studied and the influence of these eccentricities on ohmic, hysteresis and eddy current losses of PMSM are presented. In this examination, the time-domain elemental flux density waveforms and various time-domain waveforms of motor winding currents are computed using time stepping finite element method (TSFEM) for core loss and ohmic loss calculations punctually. The accuracy of obtained simulation results is verified using experimental results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/iet-epa.2008.0308

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
Ebrahimi, B. M., & Faiz, J.
Venue
IET Electric Power Applications
Published
2010-01
Volume
4
Issue
1
Pages
53-66
ISSN
  • 1751-8660 (ISSN-L)
  • 1751-8679
OpenAlex
W2075642836
Cited by
83
References
0
FWCI
9.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity. https://app.cochat.ai/papers/10.1049/iet-epa.2008.0308
The paper
Ebrahimi, B. M., & Faiz, J. (2010). Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity. IET Electric Power Applications. https://doi.org/10.1049/iet-epa.2008.0308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.