Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity
The DOI matches its Crossref record.
Abstract
Albeit permanent magnet synchronous motors (PMSMs) under static and dynamic eccentricity have been studied in few papers, so far mixed eccentricity has not been investigated. In this study, a novel index is introduced for dynamic and mixed eccentricity fault diagnosis in PMSM. This index is the amplitude of side-band components with a particular frequency pattern that is extracted from spectrum analysis of the motor torque. The index provides precise detection of the eccentricity occurrence, recognition of its type and determination of its degree. To evaluate the ability of the proposed index for the eccentricity diagnosis and estimation of its severity, first the correlation between indices, static and dynamic eccentricity degrees are calculated. The type of eccentricity is determined using k-nearest neighbour (KNN) classifier. At the next step, a three-layer artificial neural network is employed to estimate the eccentricity degree of torque profiles based on their type of eccentricity. After all, a white Gaussian noise is added to the simulated torque and robustness of the proposed index is analysed with respect to the noise variance. Meanwhile, the spectrum analysis of the stator current in faulty PMSM under static, dynamic and mixed eccentricities is studied and the influence of these eccentricities on ohmic, hysteresis and eddy current losses of PMSM are presented. In this examination, the time-domain elemental flux density waveforms and various time-domain waveforms of motor winding currents are computed using time stepping finite element method (TSFEM) for core loss and ohmic loss calculations punctually. The accuracy of obtained simulation results is verified using experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
“Additionally, it is also known that other types of rotor defects such as dynamic eccentricity can be detected by studying the same characteristic fault frequencies in the stator currents as predicted by (1) [17], [18].”
BackgroundA review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Hang, J., Zhang, J., Cheng, M., & Wang, Z. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647169 · Cited by 36
“It is successfully used to detect the stator inter-turn [6]-[7], air-gap eccentricity [8]-[9], damaged bearing [10] and demagnetization faults [11].”
Method
Metadata
- Authors
- Ebrahimi, B. M., & Faiz, J.
- Venue
- IET Electric Power Applications
- Published
- 2010-01
- Volume
- 4
- Issue
- 1
- Pages
- 53-66
- ISSN
- 1751-8660 (ISSN-L)
- 1751-8679
- OpenAlex
- W2075642836
- Cited by
- 83
- References
- 0
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity. https://app.cochat.ai/papers/10.1049/iet-epa.2008.0308
- The paper
- Ebrahimi, B. M., & Faiz, J. (2010). Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity. IET Electric Power Applications. https://doi.org/10.1049/iet-epa.2008.0308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.