Cited by 36Machine Fault Diagnosis TechniquesSensorless Control of Electric MotorsElectric Motor Design and Analysis

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Fault diagnosis of mechanical unbalance for permanent magnet synchronous motor drive system under nonstationary condition

Hang, Jun, Zhang, Jianzhong, Cheng, Ming, Wang, Zheng·2013·2013 IEEE Energy Conversion Congress and Exposition

Abstract

Motor current signature analysis based on Fast Fourier Transform (FFT) has been successfully used in a permanent magnet synchronous motor (PMSM) drive system for fault diagnosis. However, the method does not always achieve good results according to two aspects. Firstly, the amplitudes of fault harmonic components are quiet small compared with the fundamental amplitude if the fault severity is small. Then fault characters are likely to be hidden and difficult to be distinguished in the stator current. Secondly, as the speed is not constant and this causes variation on the fault characteristic frequencies where FFT is no longer suitable. This paper presents a novel method to diagnose the mechanical unbalance for a PMSM drive system under nonstationary condition, which is based on Park's vector and discrete wavelet transform. Simulations are carried out in the PMSM drive system based on MATLAB/Simulation and fault indicators are successfully extracted from the square of the stator current Park's vector modulus. The simulation results show that the proposed method can effectively detect the mechanical unbalance fault in the PMSM drive system under nonstationary condition, and the method is suitable for different control strategies.

Overview

Integrity signals

Registry

Crossref · 10.1109/ecce.2013.6647169

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In [165] and [166], DWT analysis of Park-transformed stator current confirmed effectiveness for unbalance detection under non-stationary conditions by simulation and experiments.

    “The effectiveness of this method was confirmed by simulation and experimental results carried out under non-stationary conditions.”

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Hang, J., Zhang, J., Cheng, M., & Wang, Z.
Affiliations
Southeast University (CN)
Venue
2013 IEEE Energy Conversion Congress and Exposition
Publisher
IEEE
Published
2013-09
Pages
3556-3562
OpenAlex
W2025703330
Cited by
36
References
24
Citations by year
2026: 2 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 5 · 2014: 2
FWCI
4.10
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
Keywords
permanent magnet synchronous motor, fault diagnosis, discrete wavelet transform, stator current, variable speed, fault characteristic frequency, motor drives

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›