Comparison between vibration and stator current analysis for the detection of bearing faults in asynchronous drives
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study deals with the application of vibration and motor current spectral analysis for the monitoring of rolling bearings damage in asynchronous drives. Vibration measurement is widely used to detect faulty bearings operations. However, this approach is expensive and cannot always be performed, while electrical quantities such as the machine stator current are often already measured for control and detection purposes. Signal processing methods and global indicators associated with bearing fault detection of vibration measurements are recalled. Compared to these methods, an automatic detector based on vibration spectral energy extraction is then proposed and its performances are discussed. Moreover, load torque measurements underlines that bearing faults also induce mechanical load torque oscillations. Therefore a theoretical stator current model in case of load torque oscillations is used to demonstrate the presence of phase modulation (PM) on stator currents. Frequency behaviour of the related sideband components is strongly investigated for monitoring purposes. Thus, a fault detector using the extraction of spectral energy of stator current is proposed to detect damaged bearings. This detector is then compared to the one defined on vibration signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RUBINI, R., & MENEGHETTI, U. (2001) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.2000.1330 · Cited by 323
Cited by
Saucedo-Dorantes, J. J., Delgado-Prieto, M., Ortega-Redondo, J. A., Osornio-Rios, R. A., & Romero-Troncoso, R. D. J. (2016) · Shock and Vibration · doi:10.1155/2016/5467643 · Cited by 80
“Some researches give a review of the causes and expected frequencies of vibration due to bearing defects [11, 17, 18].”
BackgroundField programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
Berriri, H., Naouar, W., Bahri, I., Slama-Belkhodja, I., & Monmasson, E. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0053 · Cited by 44
A normalized Hilbert-Huang transform technique for bearing fault detection
Osman, S., & Wang, W. (2016) · Journal of Vibration and Control · doi:10.1177/1077546314548909 · Cited by 31
Bearing fault detection in synchronous machine based on the statistical analysis of stator current
Picot, A., Obeid, Z., Regnier, J., Maussion, P., Poignant, S., & Darnis, O. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6389275 · Cited by 18
“Consequently, several studies ([6], [7], [8]) have successfully suggested to process the stator current signal, which is often available for control purposes.”
BackgroundFault Diagnosis of Motor Bearing Based on Speed Signal Kurtosis Spectrum Analysis
Ren, B., Yang, M., Chai, N., Li, Y., & Xu, D. (2019) · 2019 22nd International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921477 · Cited by 15
Metadata
- Authors
- Trajin, B., Regnier, J., & Faucher, J.
- Venue
- IET Electric Power Applications
- Published
- 2010-02
- Volume
- 4
- Issue
- 2
- Pages
- 90-100
- ISSN
- 1751-8660 (ISSN-L)
- 1751-8679
- OpenAlex
- W2117448551
- Cited by
- 56
- References
- 1
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between vibration and stator current analysis for the detection of bearing faults in asynchronous drives. https://app.cochat.ai/papers/10.1049/iet-epa.2009.0040
- The paper
- Trajin, B., Regnier, J., & Faucher, J. (2010). Comparison between vibration and stator current analysis for the detection of bearing faults in asynchronous drives. IET Electric Power Applications. https://doi.org/10.1049/iet-epa.2009.0040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.