Bearing fault detection in synchronous machine based on the statistical analysis of stator current
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In this paper, an original method to compute an indicator for efficient detection of bearing defaults in high speed synchronous machines is presented. This indicator is based on the statistical analysis of the stator current spectrum. The principle of the method is to compare the current spectrum to a healthy reference spectrum. The reference spectrum is used to center and reduce the current spectrum and provides an indication on its difference from the reference spectrum. A statistical based indicator is then constructed as the sum of the contributions of the centered reduced spectrum for different interesting frequency bands. This indicator has been tested on 2 different test campaigns, for 4 different speeds and compared a vibratory indicator. Results show that the proposed indicator evolves the same way than the vibratory indicator and provides with an efficient detection of bearing fault with only very few false alarms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diagnostic methods used in PMSMs and reported in the literature for stator current signal analysis include: FFT [116], [131], [132], [135]- [137], ZFFT [133], OA [138] and EPVA [122], DWT [134]- [136] and CWT [136].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [116]
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531 · cited 1×
“There are a lot of different failure causes in electrical machines (overview in [1]).”
BackgroundStatic-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386 · cited 1×
“However, a few work deals with bearing fault detection in permanent magnet machines ([10], [11]).”
BackgroundBasic vibration signal processing for bearing fault detection
McInerny, S. A., & Dai, Y. (2003) · IEEE Transactions on Education · doi:10.1109/te.2002.808234 · Cited by 321 · cited 1×
“Vibration analysis has first been used to detect bearing faults ([3], [4], [5]).”
MethodMechanical Load Fault Detection in Induction Motors by Stator Current Time-Frequency Analysis
Blodt, M., Chabert, M., Regnier, J., & Faucher, J. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882631 · Cited by 267 · cited 1×
“Consequently, several studies ([6], [7], [8]) have successfully suggested to process the stator current signal, which is often available for control purposes.”
BackgroundSelf-citationHenao, H., Razik, H., & Capolino, G. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847320 · Cited by 146
Stator Current-Based Bearing Fault Detection Techniques: A General Review
Zhou, W., Habetler, T. G., & Harley, R. G. (2007) · IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2007.4393063 · Cited by 74 · cited 1×
“A review of the different techniques used based on the stator current spectrum analysis is presented in [9].”
MethodTrajin, B., Regnier, J., & Faucher, J. (2010) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0040 · Cited by 56 · cited 1×
“Consequently, several studies ([6], [7], [8]) have successfully suggested to process the stator current signal, which is often available for control purposes.”
BackgroundRosero, J., Romeral, J. L., Cusido, J., Ortega, J. A., & Garcia, A. (2008) · 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2008.4522708 · Cited by 44 · cited 1×
“However, a few work deals with bearing fault detection in permanent magnet machines ([10], [11]).”
BackgroundA New Approach for Induction Motor Broken Bar Diagnosis by Using Vibration Spectrum
Sadoughi, A., Ebrahimi, M., & Rezaei, E. (2006) · SICE-ICASE International Joint Conference · doi:10.1109/sice.2006.314735 · Cited by 31
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Mbo'o, C. P., & Hameyer, K. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581139 · Cited by 135
“[8] and Obeid et al.”
Yatsugi, K., Pandarakone, S. E., Mizuno, Y., & Nakamura, H. (2023) · IEEE Access · doi:10.1109/access.2023.3254914 · Cited by 77
A Framework for Prognostics and Health Management Applications toward Smart Manufacturing Systems
Shin, I., Lee, J., Lee, J. Y., Jung, K., Kwon, D., Youn, B. D., Jang, H. S., & Choi, J.-H. (2018) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-018-0055-0 · Cited by 69
Picot, A., Obeid, Z., Régnier, J., Poignant, S., Darnis, O., & Maussion, P. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.006 · Cited by 60
“From this point of view, the statistical approach presented in [18] shows encouraging results using center-reduced variables.”
Self-citation
Metadata
- Authors
- Picot, A., Obeid, Z., Regnier, J., Maussion, P., Poignant, S., & Darnis, O.
- Affiliations
- Laboratoire Plasma et Conversion d'Energie (FR)
- Venue
- IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2012-10
- Pages
- 3862-3867
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W1966777818
- Cited by
- 18
- References
- 15
- Citations by year
- 2024: 2 · 2023: 4 · 2022: 1 · 2021: 2 · 2018: 2 · 2016: 1 · 2015: 2 · 2014: 3 · 2013: 1
- FWCI
- 3.08
- Type
- conference paper
- Language
- en
- Open access
- green
- hal.science
- Licence
- other-oa
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- bearing fault detection, synchronous machines, stator current spectrum, high-speed machines, vibration analysis, condition monitoring, false alarm reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bearing fault detection in synchronous machine based on the statistical analysis of stator current. https://app.cochat.ai/papers/10.1109/iecon.2012.6389275
- The paper
- Picot, A., Obeid, Z., Regnier, J., Maussion, P., Poignant, S., & Darnis, O. (2012). Bearing fault detection in synchronous machine based on the statistical analysis of stator current. IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society. https://doi.org/10.1109/iecon.2012.6389275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.