CoChat

Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open

Kim, K.-H., Gu, B.-G., Jung, I.-S. · 2011 · IET Electric Power Applications
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

To detect faults in an inverter-fed permanent magnet synchronous motor drive under the circumstance having faults in a stator winding and inverter switch, an online basis fault-detecting scheme during motor operation is presented. The proposed scheme is achieved by monitoring the second-order harmonic component in q-axis current and the fault is detected by comparing these components with those in normal conditions. The non-fault harmonic data in an arbitrary operating condition are determined using the linear interpolation method with several sample harmonic data pre-measured in the stage of the initial drive setup. Once the fault is detected, the operating mode is changed to identify a fault source using the phase current waveform. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control system including harmonic analysis and fault detecting algorithm is implemented using digital signal processor TMS320F28335. Without requiring an additional hardware, the fault can be effectively detected by the proposed scheme during operation so long as the steady-state condition is satisfied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/iet-epa.2010.0272

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Kim, K.-H., Gu, B.-G., & Jung, I.-S.
Venue
IET Electric Power Applications
Published
2011-07-05
Volume
5
Issue
6
Pages
529-539
ISSN
  • 1751-8660 (ISSN-L)
  • 1751-8679
OpenAlex
W2167753191
Cited by
45
References
2
FWCI
5.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.