Abstract
In order to increase the reliability and availability of wind turbines, condition monitoring and fault diagnosis are considered crucial means to achieve these goals. In this context, direct drives wind turbines based on permanent-magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. However, several statistical studies point out that power converters are a significant contributor to the overall failure rate of modern wind turbines. Accordingly, this paper presents a new algorithm for multiple open-circuit faults diagnosis in full-scale back-to-back converters, applied in PMSG drives used for wind turbine systems. The proposed method is based on a Luenberger observer and on an adaptive threshold, which can guarantee a reliable diagnosis independently of the drive operating conditions. Several simulation and experimental results using a PMSG drive with a full-scale converter are presented, showing the diagnostic algorithm effectiveness and robustness against false alarms for both generator- and grid-side converters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [269]
Citations
Cites
Luenberger, D. (1971) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1971.1099826 · Cited by 2,709 · cited 1×
“The Luenberger state observer [38] has been widely used for the control of PMSM drives [39], [40] and for three phase”
MethodAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860 · cited 1×
“A comparative study between different powers switches technologies used in wind energy conversion systems, and types of faults that can occur in these semiconductors is also presented in [5].”
BackgroundAgeing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“Fast detection times can be achieved using voltage-based techniques at the cost of additional voltage sensors [9]–[11].”
BackgroundFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“A diagnostic method based on sliding mode observer for open-circuit faults in modular multilevel converters was proposed in [25].”
MethodFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 1×
“The current space vector trajectory diameter can also be used for the localization of inverter power switch open-circuit faults [7], [8].”
Background
Research works printed but not linked: 1
- 10.1109/iemdc.1999.769220 · DOI · Paper page
Cited by
Li, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
“Detection methods for IGBT open-circuit faults have been extensively studied in literature works [27]–[31], but they are customized for traditional two-level voltage source inverters.”
MethodFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
BackgroundAn Overview on Fault Diagnosis, Prognosis and Resilient Control for Wind Turbine Systems
Gao, Z., & Liu, X. (2021) · Processes · doi:10.3390/pr9020300 · Cited by 281
“In [34], a fault diagnosis method was presented for multiple open-circuit faults in back-to-back converters of a permanent magnet synchronous generator (PMSG) drive for wind turbine systems where a Luenberger observer and adaptive threshold were used to ensure a reliable diagnosis independent of drive operation condit…”
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“shows that they may be classified as current signatures [12]– [20], [22]–[25], [30], [33]–[36] and voltage signatures based methods [26]–[29], [31], [32].”
BackgroundMethodSelf-citationGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191
“Model-based approaches such as the parity space method or observer-based methods have been widely used to detect the faults of power drive systems [8]–[10].”
Method
Metadata
- Authors
- Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J.
- Affiliations
- University of Beira Interior (PT)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-05
- Volume
- 30
- Issue
- 5
- Pages
- 2689-2702
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2067610416
- Cited by
- 212
- References
- 43
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 15 · 2023: 21 · 2022: 18 · 2021: 17 · 2020: 21 · 2019: 28 · 2018: 20 · 2017: 20 · 2016: 24 · 2015: 12
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Portuguese Foundation for Science and Technology (SFRH/BPD/87135/2012)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- open-circuit fault diagnosis, back-to-back converter, permanent magnet synchronous generator, direct-drive wind turbine, Luenberger observer, adaptive threshold, condition monitoring, generator-side converter, grid-side converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems. https://app.cochat.ai/papers/10.1109/tpel.2014.2342506
- The paper
- Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015). Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2342506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.