Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In a conventional ac motor drive using field-oriented control, a dc-link voltage, speed, and at least two current sensors are required. Hence, in the event of sensor failure, the performance of the drive system can be severely compromised. This paper presents a sensor fault-tolerant control strategy for interior permanent-magnet synchronous motor (IPMSM) drives. Three independent observers are proposed to estimate the speed, dc-link voltage, and currents of the machine. If a sensor fault is detected, the drive system isolates the faulty sensor while retaining the remaining functional ones. The signal is then acquired from the corresponding observer in order to maintain the operation of the drive system. The experimental results provided verify the effectiveness of the proposed approach.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the case of DC-link voltage sensor fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [278]
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“Faulty conditions and their remedial techniques in ac motor drives have been investigated extensively, but most of them deal with inverter [1]–[5] and stator or rotor winding faults [6]–[10].”
BackgroundInterior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives
Jahns, T. M., Kliman, G. B., & Neumann, T. W. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504786 · Cited by 939 · cited 1×
“The drive system is usually operated along the maximum-torque-per-ampere (MTPA) trajectory to maximize the overall efficiency [14].”
BackgroundNew Sliding-Mode Observer for Position Sensorless Control of Permanent-Magnet Synchronous Motor
Qiao, Z., Shi, T., Wang, Y., Yan, Y., Xia, C., & He, X. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206359 · Cited by 602
Active Flux Concept for Motion-Sensorless Unified AC Drives
Boldea, I., Paicu, M. C., & Andreescu, G.-D. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002394 · Cited by 433
Rashed, M., MacConnell, P. F. A., Stronach, A. F., & Acarnley, P. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895136 · Cited by 258
Najafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250 · cited 2×
“It makes sense because simultaneous failure of two or more sensors is a very rare incident probabilistically [27].”
BackgroundJeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240 · cited 2×
“Moreover, when a voltage sensor fault is identified, the nominal dc-bus voltage is used in [13].”
BackgroundPiippo, A., Hinkkanen, M., & Luomi, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911949 · Cited by 201 · cited 1×
“Furthermore, the proposed speed observer is less sensitive to speedestimation errors compared to the existing adaptive speed observers [15]–[18].”
Foo, G., & Rahman, M. F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030815 · Cited by 198 · cited 1×
“In-depth stability analysis and gain design of this observer is described in [21] and [22].”
BackgroundMultiphase Power Converter Drive for Fault-Tolerant Machine Development in Aerospace Applications
de Lillo, L., Empringham, L., Wheeler, P. W., Khwan-On, S., Gerada, C., Othman, M. N., & Huang, X. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036026 · Cited by 198 · cited 1×
“Faulty conditions and their remedial techniques in ac motor drives have been investigated extensively, but most of them deal with inverter [1]–[5] and stator or rotor winding faults [6]–[10].”
Background
Cited by
A Robust Observer-Based Sensor Fault-Tolerant Control for PMSM in Electric Vehicles
Kommuri, S. K., Defoort, M., Karimi, H. R., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2590993 · Cited by 408
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“More interesting solution, which consists in a special kind of adaptive observer of the DC-link voltage is presented in [278].”
BackgroundMethodWang, X., Wang, Z., Xu, Z., Cheng, M., Wang, W., & Hu, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2876400 · Cited by 263
“In [22], three independent model-based observers are proposed to estimate the speed, dc-link voltage, and phase currents of the PMSM”
Chakraborty, C., & Verma, V. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345337 · Cited by 209
Robust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140
Metadata
- Authors
- Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M.
- Affiliations
- Nanyang Technological University (SG)
- Queensland University of Technology (AU)
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-04
- Volume
- 20
- Issue
- 2
- Pages
- 855-864
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W124693401
- Cited by
- 65
- References
- 27
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 7 · 2019: 14 · 2018: 4 · 2017: 9 · 2016: 4 · 2015: 7
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Science & Engineering Faculty
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- sensor fault-tolerant control, interior permanent magnet synchronous motor, field-oriented control, state observer, velocity estimation, current estimation, sensor fault detection, fault isolation, AC motor drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives. https://app.cochat.ai/papers/10.1109/tmech.2014.2311126
- The paper
- Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M. (2015). Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2014.2311126
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.