A review of grid code technical requirements for wind farms
Open accessAbstract
This paper provides an overview of grid code technical requirements regarding the connection of large wind farms to the electric power systems. The grid codes examined are generally compiled by transmission system operators (TSOs) of countries or regions with high wind penetration and therefore incorporate the accumulated experience after several years of system operation at significant wind penetration levels. The paper focuses on the most important technical requirements for wind farms, included in most grid codes, such as active and reactive power regulation, voltage and frequency operating limits and wind farm behaviour during grid disturbances. The paper also includes a review of modern wind turbine technologies, regarding their capability of satisfying the requirements set by the codes, demonstrating that recent developments in wind turbine technology provide wind farms with stability and regulation capabilities directly comparable to those of conventional generating plants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Grid Integration of Wind Energy Conversion Systems
Heier, S. (1998) · Cited by 1,619
Grid Code, high and extra high voltage
Netz, E. O. (2006) · Medical Entomology and Zoology · Cited by 835
Weedy, B. M. (1972) · Cited by 724
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426
Impact of wind generation on the operation and development of the UK electricity systems
Štrbac, G., Shakoor, A., Black, M., Pudjianto, D., & Bopp, T. (2006) · Electric Power Systems Research · doi:10.1016/j.epsr.2006.08.014 · Cited by 251
Advanced grid requirements for the integration of wind turbines into the German transmission system
Erlich, I., Winter, W., & Dittrich, A. (2006) · 2006 IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2006.1709340 · Cited by 246
Voltage and Transient Stability Support by Wind Farms Complying With the E.ON Netz Grid Code
Ullah, N. R., Thiringer, T., & Karlsson, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907523 · Cited by 180
European Wind Energy Conference
Pritchard, C., Verbeek, V., & Rahal, Z. (2002) · Cited by 145
Design and operation of power systems with large amounts of wind power: State of the art report
Holttinen, H., Lemström, B., Meibom, P., Bindner, H. W., Orths, A., Hulle, F. V., Enßlin, C., Tiedemann, A., Hofmann, L., Winter, W., et al. (2007) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 82
Advanced grid requirements for the integration of wind farms into the Spanish transmission system
Morales, A., Robe, X., Sala, M., Prats, P., Aguerri, C., & Torres, E. (2008) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20070084 · Cited by 65
Pearmine, R., Song, Y., & Chebbo, A. M. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060003 · Cited by 22
Cited by
A review of energy storage technologies for wind power applications
Díaz-González, F., Sumper, A., Gomis-Bellmunt, O., & Villafáfila-Robles, R. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.01.029 · Cited by 1,547
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860
Rodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681
Metadata
- Authors
- Tsili, M., & Papathanassiou, S.
- Venue
- IET Renewable Power Generation
- Published
- 2009-09-08
- Volume
- 3
- Issue
- 3
- Pages
- 308-332
- ISSN
- 1752-1416 (ISSN-L)
- 1752-1424
- OpenAlex
- W2078871156
- Cited by
- 1,373
- References
- 13
- FWCI
- 44.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.