Renewable energy sources and frequency regulation: survey and new perspectives
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
As the use of renewable energy sources (RESs) increases worldwide, there is a rising interest on their impacts on power system operation and control. An overview of the key issues and new challenges on frequency regulation concerning the integration of renewable energy units into the power systems is presented. Following a brief survey on the existing challenges and recent developments, the impact of power fluctuation produced by variable renewable sources (such as wind and solar units) on system frequency performance is also presented. An updated LFC model is introduced, and power system frequency response in the presence of RESs and associated issues is analysed. The need for the revising of frequency performance standards is emphasised. Finally, non-linear time-domain simulations on the standard 39-bus and 24-bus test systems show that the simulated results agree with those predicted analytically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Grigg, C., Wong, P., Albrecht, P., Allan, R., Bhavaraju, M., Billinton, R., Chen, Q., Fong, C., Haddad, S., Kuruganty, S., et al. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.780914 · Cited by 3,054
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Grainger, J. J., & Stevenson, W. D. (1994) · Cited by 2,754
Power system control and stability.
(1979) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(79)90142-3 · Cited by 2,574
Grid Integration of Wind Energy Conversion Systems
Heier, S. (1998) · Cited by 1,619
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Lopes, J. A. P., Hatziargyriou, N., Mutale, J., Djapic, P., & Jenkins, N. (2007) · Electric Power Systems Research · doi:10.1016/j.epsr.2006.08.016 · Cited by 1,413
Energy Storage and Its Use With Intermittent Renewable Energy
Barton, J. P., & Infield, D. G. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.822305 · Cited by 1,388
A review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373
Cited by
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
Inertia response and frequency control techniques for renewable energy sources: A review
Dreidy, M., Mokhlis, H., & Mekhilef, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.170 · Cited by 853
Virtual synchronous generators: A survey and new perspectives
Bevrani, H., Ise, T., & Miura, Y. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.07.009 · Cited by 837
Self-citationIntelligent Frequency Control in an AC Microgrid: Online PSO-Based Fuzzy Tuning Approach
Bevrani, H., Habibi, F., Babahajyani, P., Watanabe, M., & Mitani, Y. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2196806 · Cited by 599
Self-citationFuture low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Smart operations of smart grids integrated with distributed generation: A review
Kakran, S., & Chanana, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.045 · Cited by 427
Energy storage systems in modern grids—Matrix of technologies and applications
Palizban, O., & Kauhaniemi, K. (2016) · Journal of Energy Storage · doi:10.1016/j.est.2016.02.001 · Cited by 379
Blockchain for Internet of Energy management: Review, solutions, and challenges
Miglani, A., Kumar, N., Chamola, V., & Zeadally, S. (2020) · Computer Communications · doi:10.1016/j.comcom.2020.01.014 · Cited by 346
Rani, P., Mishra, A. R., Pardasani, K. R., Mardani, A., Liao, H., & Streimikiene, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.117936 · Cited by 297
Rana, M. M., Uddin, M., Sarkar, M. R., Meraj, S. T., Shafiullah, G. M., Muyeen, S. M., Islam, M. A., & Jamal, T. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.107811 · Cited by 292
Bevrani, H., & Shokoohi, S. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2258947 · Cited by 292
Self-citationSerban, I., & Marinescu, C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2283298 · Cited by 274
Sharma, Y., & Saikia, L. C. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.06.005 · Cited by 257
Robust Analytic Design of Power-Synchronization Control
Harnefors, L., Hinkkanen, M., Riaz, U., Rahman, F. M. M., & Zhang, L. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2874584 · Cited by 225
“This requires either dc-side energy storage [19], [20] or a dc-side power source with headroom for increased output [21].”
Background
Metadata
- Authors
- Bevrani, H., Ghosh, A., & Ledwich, G.
- Venue
- IET Renewable Power Generation
- Published
- 2010-09-08
- Volume
- 4
- Issue
- 5
- Pages
- 438-457
- ISSN
- 1752-1416 (ISSN-L)
- 1752-1424
- OpenAlex
- W2146689117
- Cited by
- 574
- References
- 35
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.