The DOI matches its Crossref record.
The Migrate project: the challenges of operating a transmission grid with only inverter‐based generation. A grid‐forming control improvement with transient current‐limiting control
Open accessAbstract
Renewable generation is mainly connected through converters. Even if they provide more and more ancillary services to the grid, these may not be sufficient for extremely high penetrations. As the share of such generating units is growing rapidly, some synchronous areas could in the future occasionally be operated without synchronous machines. In such conditions, system behaviour will dramatically change, but stability will still have to be ensured with the same level of reliability as today. To reach this ambitious goal, the control of inverters will have to be changed radically. Inverters will need to move from following the grid to leading the grid behaviour, both in steady state and during transients. This new type of control brings additional issues on converters that are addressed in this study. A solution is proposed to allow a stable operation of the system together with a limited solicitation of inverters during transients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
Poolla, B. K., Gros, D., & Dorfler, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892290 · Cited by 400
Du, W., Chen, Z., Schneider, K. P., Lasseter, R. H., Pushpak Nandanoori, S., Tuffner, F. K., & Kundu, S. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2942491 · Cited by 377
Metadata
- Authors
- Denis, G., Prevost, T., Debry, M., Xavier, F., Guillaud, X., & Menze, A.
- Venue
- IET Renewable Power Generation
- Published
- 2017-11-21
- Volume
- 12
- Issue
- 5
- Pages
- 523-529
- ISSN
- 1752-1416 (ISSN-L)
- 1752-1424
- OpenAlex
- W2766418970
- Cited by
- 172
- References
- 0
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Migrate project: the challenges of operating a transmission grid with only inverter‐based generation. A grid‐forming control improvement with transient current‐limiting control. https://app.cochat.ai/papers/10.1049/iet-rpg.2017.0369
- The paper
- Denis, G., Prevost, T., Debry, M., Xavier, F., Guillaud, X., & Menze, A. (2018). The Migrate project: the challenges of operating a transmission grid with only inverter‐based generation. A grid‐forming control improvement with transient current‐limiting control. IET Renewable Power Generation. https://doi.org/10.1049/iet-rpg.2017.0369
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.