The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia and Fast Frequency Response
Open accessAbstract
The electric power system is witnessing a shift in the technology of generation. Conventional thermal generation based on synchronous machines is gradually being replaced by power electronics interfaced renewable generation. This new mode of generation, however, lacks the natural inertia and governor damping, which are quintessential features of synchronous machines. The loss of these features results in increasing frequency excursions and, ultimately, system instability. Among the numerous studies on mitigating these undesirable effects, the main approach involves virtual inertia (VI) emulation to mimic the behavior of synchronous machines. In this paper, explicit models of grid-following and grid-forming VI devices are developed for inertia emulation and fast frequency response in low-inertia systems. An optimization problem is formulated to optimize the parameters and location of these devices in a power system to increase its resilience. Finally, a case study based on a high-fidelity model of the South-East Australian system is used to illustrate the effectiveness of such devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiss, M. (1997) · Automatica · doi:10.1016/s0005-1098(97)00132-5 · Cited by 5,495
Mangasarian, O. L. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971255 · Cited by 3,220
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Power System Dynamics and Stability
Sauer, P. W., & Pai, M. A. (1997) · Cited by 2,154
Wind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Impact of Low Rotational Inertia on Power System Stability and Operation
Ulbig, A., Borsche, T., & Andersson, G. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.02615 · Cited by 908
Virtual synchronous generators: A survey and new perspectives
Bevrani, H., Ise, T., & Miura, Y. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.07.009 · Cited by 837
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
Understanding Small-Signal Stability of Low-Inertia Systems
Markovic, U., Stanojev, O., Aristidou, P., Vrettos, E., Callaway, D., & Hug, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3061434 · Cited by 370
Meng, L., Zafar, J., Khadem, S. K., Collinson, A., Murchie, K. C., Coffele, F., & Burt, G. M. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2940173 · Cited by 364
Resilience of renewable power systems under climate risks
Xu, L., Feng, K., Lin, N., Perera, A. T. D., Poor, H. V., Xie, L., Ji, C., Sun, X. A., Guo, Q., & O’Malley, M. (2024) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-023-00003-8 · Cited by 293
Metadata
- Authors
- Poolla, B. K., Gros, D., & Dorfler, F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-07
- Volume
- 34
- Issue
- 4
- Pages
- 3035-3046
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2898968226
- Cited by
- 400
- References
- 26
- FWCI
- 23.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia and Fast Frequency Response. https://app.cochat.ai/papers/10.1109/tpwrs.2019.2892290
- The paper
- Poolla, B. K., Gros, D., & Dorfler, F. (2019). Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia and Fast Frequency Response. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2019.2892290
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.