CoChat

Planck pre-launch status: High Frequency Instrument polarization calibration

Open access
Rosset, C., Tristram, M., Ponthieu, N., Ade, P., Aumont, J., Catalano, A., Conversi, L., Couchot, F., Crill, B. P., Désert, F.-X., Ganga, K., Giard, M., Giraud-Héraud, Y., Haïssinski, J., Henrot-Versillé, S., Holmes, W., Jones, W. C., Lamarre, J.-M., Lange, A., Leroy, C., Macías-Pérez, J., Maffei, B., de Marcillac, P., Miville-Deschênes, M.-A., Montier, L., Noviello, F., Pajot, F., Perdereau, O., Piacentini, F., Piat, M., Plaszczynski, S., Pointecouteau, E., Puget, J.-L., Ristorcelli, I., Savini, G., Sudiwala, R., Veneziani, M., Yvon, D. · 2010 · Astronomy and Astrophysics
Cited by 113

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization (ΔP/Tcmb ~ 4 × 10-6 for P either Q or U and Tcmb 2.7 K) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the cosmic microwave background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the E-mode spectrum (up to ~ 1500) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of the instrument as well as the combination of different detectors. We use this method to propagate errors through to the CMB angular power spectra in the particular case of Planck-HFI, and to derive constraints on polarization parameters. We show that in order to limit the systematic error to 10% of the cosmic variance of the E-mode power spectrum, uncertainties in gain, polarization efficiency and detector orientation must be below 0.15%, 0.3% and 1° respectively. Pre-launch ground measurements reported in this paper already fulfill these requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1051/0004-6361/200913054

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 113

Metadata

Authors
Rosset, C., Tristram, M., Ponthieu, N., Ade, P., Aumont, J., Catalano, A., Conversi, L., Couchot, F., Crill, B. P., Désert, F.-X., Ganga, K., Giard, M., Giraud-Héraud, Y., Haïssinski, J., Henrot-Versillé, S., Holmes, W., Jones, W. C., Lamarre, J.-M., Lange, A., Leroy, C., Macías-Pérez, J., Maffei, B., de Marcillac, P., Miville-Deschênes, M.-A., Montier, L., Noviello, F., Pajot, F., Perdereau, O., Piacentini, F., Piat, M., Plaszczynski, S., Pointecouteau, E., Puget, J.-L., Ristorcelli, I., Savini, G., Sudiwala, R., Veneziani, M., & Yvon, D.
Venue
Astronomy and Astrophysics
Publisher
EDP Sciences
Published
2010-09
Volume
520
Pages
A13
ISSN
  • 0004-6361 (ISSN-L)
  • 1432-0746
OpenAlex
W2155855136
Cited by
113
References
3
FWCI
9.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Planck pre-launch status: High Frequency Instrument polarization calibration. https://app.cochat.ai/papers/10.1051/0004-6361/200913054
The paper
Rosset, C., Tristram, M., Ponthieu, N., Ade, P., Aumont, J., Catalano, A., Conversi, L., Couchot, F., Crill, B. P., Désert, F.-X., Ganga, K., Giard, M., Giraud-Héraud, Y., Haïssinski, J., Henrot-Versillé, S., Holmes, W., Jones, W. C., Lamarre, J.-M., Lange, A., . . . Yvon, D. (2010). Planck pre-launch status: High Frequency Instrument polarization calibration. Astronomy and Astrophysics. https://doi.org/10.1051/0004-6361/200913054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.