Large-volume conventional magnetic shields
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Increasing demand for low-field regions of large volumes has resulted in the construction of many magnetically-shielded walk-in rooms. Most have been of the cubic, two-layer high-μ type, but several have used three layers, including one built by this author about three years ago. This room used several innovations, including "shaking" to increase the permeability of the magnetic sheets. The shielding characteristics and performance of this room were measured in some detail, and the results of these measurements will be discussed. These results indicate the improvements in room shielding which could profitably be made if one wished to push to the shielding limit for conventional (non-superconducting) walk-in shields. At MIT, we decided to build such a limiting low-field room in which we hope eventually to reach a B-vector amplitude of 1 × 10-8 gauss (rms, including dc) at the room center. This room is now under construction (2) and will be a national facility. It is roughly spherical in shape, with 26 sides, and has three layers of high-μ sheets and two layers of pure aluminium. The inner and outer diameters are 2.5 meters and 4.0 meters. The concepts and design details of this room will be discussed, along with the planned uses of this room for the next several years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Shielded Facility for Low-Level Magnetic Measurements
Cohen, D. (1967) · Journal of Applied Physics · doi:10.1063/1.1709590 · Cited by 38
Self-citation
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Superconducting quantum interference device instruments and applications
Fagaly, R. L. (2006) · Review of Scientific Instruments · doi:10.1063/1.2354545 · Cited by 594
Applications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
Presentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Metadata
- Authors
- Cohen, D.
- Venue
- Revue de Physique Appliquée
- Publisher
- EDP Sciences
- Published
- 1970
- Volume
- 5
- Issue
- 1
- Pages
- 53-58
- ISSN
- 0035-1687 (ISSN-L)
- OpenAlex
- W1984863480
- Cited by
- 78
- References
- 1
- FWCI
- 1.46
- Type
- journal article
- Language
- fr
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large-volume conventional magnetic shields. https://app.cochat.ai/papers/10.1051/rphysap:019700050105300
- The paper
- Cohen, D. (1970). Large-volume conventional magnetic shields. Revue de Physique Appliquée. https://doi.org/10.1051/rphysap%3A019700050105300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.